Siemens SIMATIC 505 User & Programmers Manual page 129

Turboplastic module
Hide thumbs Also See for SIMATIC 505:
Table of Contents

Advertisement

Process/Part::
Machine:
Function Address
Constants
1 (WY5)
2
3
4
5
6
7
8
9
10
11
12
13
14
Clamp Closing Profile Data Log
Mold:
Loc Description
1
Module sample rate
2
Max profile time
3
Lock-over velocity
4
Lock-over pressure
5
Lock-over time
6
Lock-over scaling factor
7
K1
8
K2
9
K3
10
Velocity/pressure operation bits
Bits 1–2
PID algorithm for velocity
Bits 3–4
Filter for velocity calculation
Bit 5
Voltage range for flow command
Bit 6
Not used this profile
Bit 7
Not used this profile
Bit 8
Velocity ramping
Bits 9–10
PID algorithm for pressure
Bit 11
Pressure ramping
Bit 12
Output range
Bit 13
Voltage range for pressure
Bits 14–16
Not used this profile
11
K1
12
K2
13
K3
Velocity/pressure data acquisition
14
bits
Bits 1–3
SPC/SQC diagnostics
Bits 4–7
Velocity filter constants
Bit 8
Bias option
Bit 9
Reverse acting for velocity
Bit 10
Reverse acting for pressure
(velocity loop gain)
(velocity loop rate)
(velocity loop reset)
(pressure loop gain)
(pressure loop rate)
(pressure loop reset)