Humidifier tub - Material:
65W power supply unit
AC input range
DC output
Typical power consumption
Peak power consumption
Class of equipment
Environmental conditions
Operating temperature
Operating humidity
Operating altitude
Storage pressure/Storage altitude
Storage and transport temperature
Storage and transport humidity
Air Filter
Standard:
Hypoallergenic:
Electromagnetic compatibility
The AirSense 11 complies with all applicable electromagnetic compatibility requirements (EMC) according to IEC 60601-1-2:2014,
for residential, commercial and light industry environments.
Portable and mobile RF communications equipment should be used no closer to any part of the machine, including cables, than the
recommended 3.94" (10 cm) separation distance.
The AirSense 11 has been designed to meet EMC standards. However, should you suspect that the device performance (eg.
pressure or flow) is affected by other equipment, move the device away from the possible cause of interference.
Information regarding the electromagnetic emissions and immunity of this ResMed device can be found in
ResMed.com/downloads/devices.
IEC 60601-1 (Edition 3.1) classification
Class II (double insulation), Type BF, Ingress protection IP22.
Supplemental oxygen maximum flow
15 L/min
Aircraft use
ResMed confirms that the machine meets the Federal Aviation Administration (FAA) requirements (RTCA/DO-160, section 21,
category M; RTCA-DO-160, section 20, category T) for all phases of air travel.
Design life
Device, power supply unit:
Standard humidifier tub:
Air tubing:
General
The patient is an intended operator.
38
Injection molded plastic, stainless steel and silicone seal
100-240v, 50-60Hz, 2.0A
115V, 400Hz, 1.5A (for aircraft use)
24 VDC ± 1 VDC, 2.71A
56.1W (111.5VA)
73.2W (137.6VA)
Class ll
+41°F to +95°F (+5°C to +35°C)
Note: The airflow for breathing produced by this therapy device can be
higher than the room temperature. Under extreme ambient temperature
conditions (104°F/40°C) the device remains safe.
10 to 95% relative humidity, non-condensing
Sea level to 9,870' (3,010 m); air pressure range 1060 hPa to 700 hPa
1060 to 700 hPa relative humidity, non-condensing
-13°F to +158°F (-25°C to +70°C)
5 to 95% relative humidity, non-condensing
Material: Polyester non woven fiber
Average arrestance: >75%, when tested to EN779.
Material: Blended synthetic fibers in a polypropylene carrier
Efficiency: >80% (average) when tested to EN13274-7.
Note: The use of a ResMed approved hypoallergenic filter will result in a
small reduction in the accuracy of the delivered pressure at high leaks.
5 years
6 months
6 months