STORAGE AND TRANSPORT

Always store the tool in its clean, dry carrying case when not in use, and during transport.
The battery cartridge and the battery charging unit should be protected against humidity and dust.

TROUBLESHOOTING

Before You Begin:
1.
Make sure that the battery is charged. Recheck the battery after several minutes to make
sure the battery is holding its charge.
2.
Use a nonflammable contact cleaner or pencil eraser to clean the electrical contacts on
the battery and crimping tool.
3.
Reinstall the battery and check the tool again.
Problem
Tool is inoperative.
Dies stop during
operation.
LED glows for 20
seconds
Tool loses oil.

DISCONTINUATION OF USE / DISPOSAL

The battery cartridge must be specially disposed of according environmental Battery
Guidelines.
For the disposal of the remaining parts, please reference environmental guidelines.
Because of possible environmental damage, we recommend disposal of the tool by
professional companies.
ATTENTION:
USE OF THE BATTERY CARTRIDGE (CT-2600BC) and
CHARGING UNIT (CT-2600CHR or CT-2600CHR/E
The charging unit is run with a nominal voltage of 120 V (CT-2600CHR), or (230 V for
CT-2600CHR/E) and a frequency of 50-60 Hz. New batteries must be charged prior to use. To remove
the battery, actuate the battery lock and pull it out of the tool. To charge the battery, connect the power
plug of the charging unit with the power supply and slide the battery into the charging unit. The
charging time is 40 minutes. The charging level of the battery cartridge can be checked by the right
LED (multi-color) of the charging unit.
CT-2600 & CT-2600/E
CT-2600 and CT-2600/E
Probable Cause
Dirt, contaminants, etc., in ram
area of tool.
Crimping tool battery contacts
damaged.
Tool components worn or
damaged.
Oil level is low.
Air in hydraulic system.
Battery charge low.
Damaged internal seal.
PA26001A01_02
Probable Remedy
Clean tool.
Reform contacts.
Return tool to PANDUIT Tool Division.
Return tool to PANDUIT Tool Division.
Pull trigger and hold retract button
simultaneously. Hold for approximately 10
seconds.
Charge or replace battery.
Return tool to PANDUIT Tool Division.
Do not dispose of the unit in your
residential or commercial waste, as it
would be hazardous to the
environment.