Please connect the NC port of the alarm sensor to the DVR alarm input(ALARM)
Use the same ground with that of DVR if you use external power to the alarm device.

2.7.3 Alarm Output Port

Provide external power to external alarm device.
To avoid overloading, please read the following relay parameters sheet carefully.
RS485 A/B cable is for the A/B cable of the PTZ decoder.
T+,T-,R+,R- are four-wire double duplex RS485 port.
T+ T-: output wire
R+ R-: input wire
Model
Material of the touch
Rated switch
capacity
Maximum
switch power
Rating
(Resistance
Maximum
Load)
switch voltage
Maximum
switch
currency
Between
touches
Insulation
Between touch
and winding
Turn-on Time
Turn-off Time
Longevity
Mechanical
Electrical
Figure 2-2

Relay Specification

HFD23/005-1ZS
AgNi+ gold-plating
30V DC 1A/125V AC 0.5A
62.5VA/30W
125V AC/60V DC
2A
400VAC 1 minute
1000VAC 1 minute
5ms max
5ms max
7
1×10
times
times/MIN)
5
1×10
times
times/MIN)
HRB1-S-DC5V
AuAg10/AgNi10/CuNi30
24V DC 1A/125V AC 2A
250VA/48W
125V AC/60V DC
2A
500VAC 1 minute
1000VAC 1 minute
5ms max
5ms max
6
300
5×10
times
times/MIN)
4
30
2.5×10
times
times/MIN)
300
30
16