Syrup 1 or Syrup 2 Message (
If either freeze cylinder is out of syrup, a warning will "Beep" seven times. The message display will
indicate Syrup 1 or Syrup 2. This indicates the syrup supplying that freeze cylinder must be replaced.
Proceed as follows:
Tank System
A. Remove the empty syrup tank by disconnecting the syrup tube first, then the CO
B. Rinse the disconnects in warm water to remove any syrup residue.
C. Move a full tank into position and connect the CO
Bag-in-Box System
D. Disconnect the syrup tube from the empty bag-in-box and remove the empty bag-in-box.
E. Install a full bag-in-box and connect the syrup tube. Proceed to step F.
FCB Control Panel
F. At the FCB panel, press and hold the Hidden Security Switch for 10 seconds. This unlocks the
panel and allows programming.
G. Press Off 1 or Off 2 depending on which cylinder is being replenished.
H. Press and hold the Fill 1 or Fill 2 until the Syrup 1 or Syrup 2 message goes out.
I. If the Syrup 1 or Syrup 2 message does not change to Fill 1, or Fill 2, repeat step H until it
does.
J. Press Autoblend 1 or Autoblend 2. The blend tank will fill automatically.
K. Slowly pull the relief valve ring on the faceplate to relieve the CO
filling. When the cylinder is full, liquid will run from the tube.
L. Press Auto 1 or Auto 2 to start the freeze process. The freeze cylinder beaters and the refrigera-
tion system will start automatically. Do not start unless the freeze cylinders are FULL.
M. Press and hold the Hidden Security Switch for seven seconds. This will re-lock the panel so
unauthorized persons cannot disturb the settings. Test by pressing the Off 1 switch. Nothing
should happen.
See back for tank illustration and freeze cylinder location
560000853
FCB Operator Instructions
Applies to V2, V3 & V3+ Units
see back for freeze cylinder location
2
1
Message Display
)
first, then the syrup tube. Proceed to step F.
pressure while the cylinder is
2
tube.
2
8/93

Advertisement

loading

Summary of Contents for Cornelius FCB V2

  • Page 1 FCB Operator Instructions Applies to V2, V3 & V3+ Units Hidden Security Message Display Switch Syrup 1 or Syrup 2 Message ( see back for freeze cylinder location If either freeze cylinder is out of syrup, a warning will “Beep” seven times. The message display will indicate Syrup 1 or Syrup 2.