38YL + 40JX
Heat pump
Pompa di calore
Pompe à chaleur
Wärmepumpe
Bomba de calor
Table 4 - Electrical data (heat pump)
38YL
+
40JX
Operation voltage
CONSUMPTION
Nominal (on cooling) *
Nominal (on heating) **
Máximum (on coolig) ***
Máximum (on heating) ****
On short circuit
NOTAS:
*
Outdoor dry bulb temp. = 35
**
Outdoor wet bulb temp. = 6
o
*** Outdoor dry bulb temp. = 46
**** Outdoor wet bulb temp. = 18
Tabella 4 - Dati elettrici (Pompa di calore)
38YL
+
40JX
Tensione nominale
ASSORBIMENTO
Nominale (raffrescamento) *
Nominale (riscaldamento) **
Massimo (raffrescamento) ***
Massimo (riscaldamento) ****
Corrente di spunto
NOTAS:
*
Temperatura esterna b.s. = 35
**
Temperatura esterna b.u. = 6
*** Temperatura esterna b.s. = 46
**** Temperatura esterna b.u. = 18
09
+
009
V/Ph/Hz
kW
1,00
Amp
4,52
kW
0,92
Amp
4,16
kW
1,20
Amp
5,43
kW
1,10
Amp
4,98
Amp
28,5
o
o
C; Indoor wet bulb temp. = 19
C.
C; Indoor dry bulb temp. = 21
o
C.
o
o
C; Indoor wet bulb temp. = 21
C.
o
o
C; Indoor dry bulb temp. = 24
C.
09
+
009
V/Ph/Hz
kW
1,00
Amp
4,52
kW
0,92
Amp
4,16
kW
1,20
Amp
5,43
kW
1,10
Amp
4,98
Amp
28,5
o
C; Temperatura interna b.u = 19
o
C; Temperatura interna b.s. = 21
o
C; Temperatura interna b.u. = 21
o
C; Temperatura interna b.s. = 24
12
18
24
+
+
+
012
018
024
1.22
1.79
2.20
5.52
8.10
10.10
1.10
1.67
2.20
4.97
7.56
10.10
1.46
2.15
2.69
6.60
9.73
12.17
1.32
2.00
2.04
5.97
9.05
9.23
35.0
51.5
78.0
12
18
24
+
+
+
012
018
024
1,22
1,79
2,20
5,52
8,10
10,10
1,10
1,67
2,20
4,97
7,56
10,10
1,46
2,15
2,69
6,60
9,73
12,17
1,32
2,00
2,04
5,97
9,05
9,23
35,0
51,5
78,0
o
C.
o
C.
o
C.
o
C.
10
28
36
48
+
+
028
036
048
/
/
2.77
3.48
4.0
12.53/4.77
15.75/5.24
13.5/7.95
2.61
2.74
3.80
11.80/3.93
12.40/4.13
13.7/7.9
3.32
4.17
4.43
15.02/5.0
18.87/6.28
14.8/8.53
3.13
3.29
5.11
14.16/4.71
14.89/4.95
17.1/9.84
84.5/47.5
108.0/49.0
103.0/53.0
Outdoor unit operation voltage
Outdoor unit operation voltage
Outdoor unit operation voltage
28
36
48
+
+
028
036
048
/
/
2,77
3,48
4,0
12,53/4,77
15,75/5,24
13,5/7,95
2,61
2,74
3,80
11,80/3,93
12,40/4,13
13,7/7,9
3,32
4,17
4,43
15,02/5,0
18,87/6,28
14,8/8,53
3,13
3,29
5,11
14,16/4,71
14,89/4,95
17,1/9,84
84,5/47,5
108,0/49,0
103,0/53,0
Unità esterna con tensione nominale 230V ~ 50Hz
Unità esterna con tensione nominale 400V 3N~ 50Hz
Unità esterna con tensione nominale 230V 3N~ 50Hz
60
+
+
060
/
/
5.15
18.4/10.6
4.65
17.2/9.90
6.58
23.6/13.58
6.0
21.5/12.38
124.0/64.0
230V ~ 50Hz
400V 3N~ 50Hz
230V 3N~ 50Hz
60
+
+
060
/
/
5,15
18,4/10,6
4,65
17,2/9,90
6,58
23,6/13,58
6,0
21,5/12,38
124,0/64,0