20
Cylinder Connection: Ensure the gas regulator hose is
kink free. Remove the cap or plug from the cylinder fuel
valve. Insert the POL regulator nipple onto the Cylinder
valve. Tighten anti-clockwise. Leak test all joints prior
to using the appliance. A leak test must be performed
annually and each time a cylinder is hooked up or if a part
of the gas system is replaced.
If this appliance is to be connected directly to a house
propane gas supply line, ensure a 2.75kPa regulator is
incorporated into the gas system.
CAUTION!
!
Make sure cylinder valve is in its full off position.
Check cylinder valve features to ensure it has proper
external mating threads.
Inspect hose thoroughly for damage. Never attempt to use damaged or plugged equipment. See
your local LP Gas Dealer for repairs.
Locate the hose out of pathways where people may trip over it or in areas where the hose may be
subject to accidental damage.
Open cylinder valve fully (counter-clockwise). Turn the on/off valve at the unit slowly to the on
position and use a soapy water solution to check all connections for leaks as indicated in the
diagrams before attempting to light the appliance. If a leak is found, turn tank valve off and do not
use the appliance until repairs can be made.
!
WARNING!
appliance.
LP (Propane) Gas Cylinder Mounting
To Prevent the LP-gas cylinder from tipping over, ensure the cylinder support ring is on a level surface.
Place the cylinder into the support ring and tighten the thumb screw to secure.
Cylinder Retaining Bracket
1. Fasten the bracket to the bottom of the propane bottle using bolt and nut supplied.
2. Tighten the lag screw into the mounting surface leaving
approximately 1/4" (6mm) of thread above the surface.
3. Slide propane bottle into position so that the bracket slides
under the head of the lag screw.
4. Tighten the lag screw onto the bracket.
5. For fastening to a concrete surface a concrete anchor will be
required. (Not supplied)
www.napoleon.com
A fire will result if the gas supply hose makes contact with the underside of the
N415-0346-AU FEB 23.21

Advertisement