Napoleon Galaxy Series Manual page 18

Outdoor gas fireplace
Hide thumbs Also See for Galaxy Series:
Table of Contents

Advertisement

18
7. Reconnect the stainless steel flex connector to the orifice and tighten using (2) wrenches.
8. Place the glass tray over the burner and fasten to the firepace with the screws removed in step 2.
9. Remove the NG regulator (if fitted). Connect the test point to the inlet fitting.
10. Fill out the conversion label included with your fireplace and apply it to the inside of the control panel
access door.
11. A leak test must be performed according to the leak testing instructions found in the manual.
!
WARNING!
may occur.
Connection to Propane Gas Supply
This fireplace may be connected to Propane in accordance with AS5601.1.
The following section incorporates guidelines for Propane supply via LPG cylinder.
Enclosures For LP (Propane) Gas Supply Systems
If you build an enclosure for an LP gas cylinder, follow these recommended specifications. You must also
follow local codes.
An enclosure for an LP-gas cylinder shall be ventilated by openings at both the upper and lower levels of
the enclosure.
This shall be accomplished by one of the following:
One side of the enclosure shall be completely open;
OR
For an enclosure having four sides, a top, and a bottom:
a) At least two ventilation openings shall be provided in the sidewall of the enclosure. The upper opening
shall be located within 5 in (127 mm) of the top of the enclosure. The lower opening shall be provided at
floor level of the enclosure.
b) The bottom of the lower opening shall be 1 in (25.4 mm) or less from the floor level and the upper edge
no more than 5 in (127 mm) above the floor level.
c) Every opening shall have minimum dimensions so as to permit the entrance of a 1/8 inch (3.2mm)
diameter rod.
d) The bottom of the low level (set of) opening(s) shall be at the enclosure base with the upper edge no
more than 125mm above the base.
www.napoleon.com
If these instructions are not followed exactly, a fire causing death or serious injury
PRESSURE TEST POINT FITTING
N415-0346-AU FEB 23.21