Ampacity Wire Sizing

The required wire size of a service con-
ductor can be determined based on the
specified electrical requirements and
the [WireSz] key. The wire size is auto-
matically recalculated whenever the
wire insulation (temperature) ratings or
wire material (copper or aluminum)
types are revised. Wire sizing is based
on the requirements defined in NEC
Tables 310-16 and 310-17.
Wire Sizing Based
on Insulation Rating
Wiring is being installed in a 240 volt,
single-phase system rated at 30 kVA.
What is the wire size needed if you use
60°C copper wire?
Steps
Keystrokes
Clear calculator
[On/C] [On/C]
Set to 1-phase
[Set] 1
Û&
Set to 60
[Set] 6
Enter kVA
30 [kilo-] [VA]
Enter volts
240 [Volts]
Find amps
[Amps]
Find CU wire size [WireSz]
24 — ElectriCalc LT
Display
0.
1 PH
1Ø 60 Cu 1 PH
30. KVA
240. VOLT
125. AMPS
0 CU
AWG WIRE SIZE