Ametek DCS-E 1kW Series Programming Manual

Ametek DCS-E 1kW Series Programming Manual

Hide thumbs Also See for DCS-E 1kW Series:

Advertisement

Quick Links

DCS-E 1kW Series,
DLM-E 3kW & 4kW
s
Power Supplie
M51A Option: Isolated Analog
Programming Manual
M362250-01 Rev C
www.programmablepower.com

Advertisement

Table of Contents
loading

Summary of Contents for Ametek DCS-E 1kW Series

  • Page 1 DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplie M51A Option: Isolated Analog Programming Manual M362250-01 Rev C www.programmablepower.com...
  • Page 5 About AMETEK AMETEK Programmable Power, Inc., a Division of AMETEK, Inc., is a global leader in the design and manufacture of precision, programmable power supplies for R&D, test and measurement, process control, power bus simulation and power conditioning applications across diverse industrial segments.
  • Page 6 This page intentionally left blank.
  • Page 7 Neither AMETEK Programmable Power Inc., San Diego, California, USA, nor any of the subsidiary sales organizations can accept any responsibility for personnel, material or inconsequential injury, loss or damage that results from improper use of the equipment and accessories.
  • Page 8 This page intentionally left blank.
  • Page 9: Table Of Contents

    CONTENTS SECTION 1 M51A OPTION OVERVIEW ..........1-1 Introduction ...................... 1-1 General Description ..................1-1 Specifications....................1-2 1.3.1 Electrical Specifications ............... 1-2 1.3.2 Supplemental Characteristics .............. 1-2 SECTION 2 ISOLATED ANALOG PROGRAMMER OPERATION ..2-1 SW1 Switch ..................... 2-1 2.1.1 SW1 Switch Setup ................2-2 ISOLATED ANALOG PROGRAMMER Connector (J4)........
  • Page 10 Contents DLM-E Series and DCS-E Series LIST OF TABLES Table 2–1. SW1 SETUP Switch.................. 2-1 Table 2–2. ISOLATED ANALOG PROGRAMMER Connector Pinout ......2-3 Table 2–3. Remote Monitoring................. 2-19 Table 2–4. Remote Digital Status Signals ............... 2-19 LIST OF FIGURES Figure 2–1.
  • Page 11: Section 1 M51A Option Overview

    M51A OPTION OVERVIEW Introduction This manual is to be used in conjunction with the DCS-E 1kW Series & DCS-E 1.2kW Series DC Power Supplies Operation Manual, Sorensen Document No. M362500-01 and the DLM-E 3Kw & 4Kw Series Power Supplies Operation Manual, Sorensen Document No. M362000-01.
  • Page 12: Specifications

    M51A Option Overview DLM-E Series and DCS-E Series Specifications 1.3.1 Electrical Specifications Remote Voltage Programming Accuracy, 0-5/10V Inputs: Output Voltage: 0.5% of Vmax Output Current: 0.75% of Imax OVP: 1.0% of 1.1 X Vmax Remote 4-20 mA Programming Accuracy: Output Voltage: 1.0% of Vmax Output Current: 1.0% of Imax Burden voltage of 6.25 VDC (312.5 ohms nominal) 1.3.2...
  • Page 13: Sw1 Switch

    SECTION 2 ISOLATED ANALOG PROGRAMMER OPERATION SW1 Switch The SW1 SETUP switch is accessible from the rear panel of the unit. It provides user selection of the programming/monitoring ranges and shutdown logic signal level. Setting a switch to the 1 or 0 position changes a range.
  • Page 14: Sw1 Switch Setup

    Isolated Analog Programmer Operation DLM-E Series and DCS-E Series 2.1.1 SW1 Switch Setup The following sections describe the functions of the various switch positions: Voltage Programming Range Select (V PROG): SW1-1, ON (1) position, selects 0-5VDC programming range for the output voltage. Must also be set to ON (1) position when the Isolated Analog Programmer is wired for 4-20mA input programming.
  • Page 15: Isolated Analog Programmer Connector (J4)

    DLM-E Series and DCS-E Series Isolated Analog Programmer Operation ISOLATED ANALOG PROGRAMMER Connector (J4) The ISOLATED ANALOG PROGRAMMER connector is a 25-position female Subminiature-D type. The table below defines each pins function. Function ANALOG-CONTROL input Isolated Analog Common OVP programming input Voltage monitor output, 4-20mA VOLTAGE-MODE status output Isolated Analog Common...
  • Page 16: Isolated Analog Programmer Functions

    Isolated Analog Programmer Operation DLM-E Series and DCS-E Series 2.2.1 ISOLATED ANALOG PROGRAMMER Functions The following sections describe the functions of the various signals of the ISOLATED ANALOG Programmer. Circuit is SELV, and all connections have electrical isolation from the output of the unit.
  • Page 17 DLM-E Series and DCS-E Series Isolated Analog Programmer Operation Analog Programming Signals OVP PROGRAMMING INPUT: Pin-3, an input signal of 0-5 volts or 0-10 volts (user selectable with switch SW1-3) programs the OVP threshold from 5-110% of full scale output voltage. Signal return is at J4-12.
  • Page 18 Isolated Analog Programmer Operation DLM-E Series and DCS-E Series Auxiliary Sources AUXILIARY DC OUTPUT: Pin-15, 16VDC source for use with logic and programming circuits. Source capability is adequate to provide for full scale programming of output voltage, current, or OVP when the user connects it to the appropriate programming input(s). Source is referenced to Pin-6.
  • Page 19: Remote Programming Configuration

    DLM-E Series and DCS-E Series Isolated Analog Programmer Operation Remote Programming Configuration 2.3.1 Voltage Source Programming of Output Voltage SW1 Switch Settings SW1-1 ON (1)= 0–5V SW1-1 OFF (0)= 0–10V Set up for voltage source programming of the output voltage as follows: Set SW1-1, V PROG, to ON (1) for 0-5VDC programming range.
  • Page 20: Voltage Source Programming Of Output Current

    Isolated Analog Programmer Operation DLM-E Series and DCS-E Series 2.3.2 Voltage Source Programming of Output Current SW1 Switch Settings SW1-2 ON (1) = 0–5V SW1-2 OFF (0)= 0–10V Set up for voltage source programming of the output voltage as follows: Set SW1-2, I PROG, to ON (1) for 0-5VDC programming range.
  • Page 21: Voltage Source Programming Of Ovp

    DLM-E Series and DCS-E Series Isolated Analog Programmer Operation 2.3.3 Voltage Source Programming of OVP SW1 Switch Settings SW1-3 ON (1) = 0–5V SW1-3 OFF(0) = 0–10V Set up for voltage source programming of OVP as follows: Set SW1-3, OVP PROG, to ON (1) for 0-5VDC programming range. Set SW1-3, OVP PROG, to OFF (0) for 0-10VDC programming range.
  • Page 22: Resistance Programming Of Output Voltage

    Isolated Analog Programmer Operation DLM-E Series and DCS-E Series 2.3.4 Resistance Programming of Output Voltage SW1 Switch Settings SW1-1 ON (1) = 0–5K Set up for resistance programming of the output voltage as follows: Set SW1-1, V PROG, to ON (1) for 0-5VDC programming range. Connect the external programming resistance, 0-5kΩ, to the ISOLATED ANALOG PROGRAMMER connector, J4, from Pin-9 to Pin-12.
  • Page 23: Resistance Programming Of Output Current

    DLM-E Series and DCS-E Series Isolated Analog Programmer Operation 2.3.5 Resistance Programming of Output Current SW1 Switch Settings SW1-2 ON (1) = 0–5K Set up for resistance programming of the output current as follows: Set SW1-2, I PROG, to ON (1) for 0-5VDC programming range. Connect the external programming resistance, 0-5kΩ, to the ISOLATED ANALOG PROGRAMMER connector, J4, from Pin-10 to Pin-12.
  • Page 24: Resistance Programming Of Ovp

    Isolated Analog Programmer Operation DLM-E Series and DCS-E Series 2.3.6 Resistance Programming of OVP SW1 Switch Settings SW1-3 ON (1) = 0–5K Set up for resistance programming of the output voltage as follows: Set SW1-3, OVP PROG, to ON (1) for 0-5VDC programming range. Connect the external programming resistance, 0-5KΩ, to the ISOLATED ANALOG PROGRAMMER connector, from Pin-3 to Pin-12.
  • Page 25: 4-20Ma Current Source Programming Of Output Voltage

    DLM-E Series and DCS-E Series Isolated Analog Programmer Operation 2.3.7 4-20mA Current Source Programming of Output Voltage SW1 Switch Settings SW1-1 ON (1) = 4-20mA 4-20mA Set up for 4-20 mA programming of the output voltage as follows: Set SW1-1, V PROG, to ON (1) for 4-20mA programming range. Connect the external programming current source to the ISOLATED ANALOG PROGRAMMER connector, J4, with the source to Pin-9 and the return to Pin-25.
  • Page 26: 4-20Ma Current Source Programming Of Output Current

    Isolated Analog Programmer Operation DLM-E Series and DCS-E Series 2.3.8 4-20mA Current Source Programming of Output Current SW1 Switch Settings SW1-2 ON (1) = 4-20mA 4-20mA Set up for 4-20 mA programming of the output current as follows: Set SW1-2, I PROG, to ON (1) for 4-20mA programming range. Connect the external programming current source to the ISOLATED ANALOG PROGRAMMER connector, J4, with the source to Pin-10 and the return to Pin-13.
  • Page 27: Programming The Shutdown Function

    DLM-E Series and DCS-E Series Isolated Analog Programmer Operation 2.3.9 Programming the Shutdown Function Figure 2–3. Using Shutdown with a DC Input (Positive Logic) 2.3.10 TTL Shutdown Set up for Shutdown input signal as follows: Connect the shutdown signal source to the ISOLATED ANALOG PROGRAMMER connector, J4, with positive to Pin-14 and the return to Pin-2.
  • Page 28: Shutdown Application - Contact Closure

    Isolated Analog Programmer Operation DLM-E Series and DCS-E Series 2.3.11 Shutdown Application – Contact Closure An external relay, whether normally open or normally closed, may be used to activate the Shutdown circuit. Either positive or negative logic may be used. Set up for Shutdown input signal as follows: Connect one side of the external relay to pin 15 (+16 VDC Auxiliary Output) on connector J4.
  • Page 29: Figure 2-5. Using Shutdown With Contact Closure Of A Normally Open Relay

    DLM-E Series and DCS-E Series Isolated Analog Programmer Operation Figure 2–5. Using Shutdown with Contact Closure of a Normally OPEN Relay (SW1-6 OFF) Figure 2–6. Using Shutdown with Contact Closure of a Normally CLOSED Relay (SW1-6 ON) M51A Option 2-17...
  • Page 30: Local/Remote Application

    Isolated Analog Programmer Operation DLM-E Series and DCS-E Series 2.3.12 Local/Remote Application An external relay or switch may be used to select the Local/Remote function. Connect one side of the contacts to Pin-15 (+16 VDC Auxiliary Output) on connector J4. Connect the other contact to Pin-2.
  • Page 31: Remote Monitoring

    DLM-E Series and DCS-E Series Isolated Analog Programmer Operation Remote Monitoring Analog signals are available for monitoring the output voltage and current. These signals vary proportionally to the output parameters, and have user selectable ranges of 0-5VDC, 0-10VDC, or 4-20mA for an output change from zero to full scale. Refer to Table 2–3 for information on configuring the monitors.
  • Page 32 Isolated Analog Programmer Operation DLM-E Series and DCS-E Series This page intentionally left blank. 2-20 M51A Option...