Mounting Installation

DANGER
Always disconnect, lock and tag power source before
installing or servicing. Failure to disconnect power
source can result in fire, shock or serious injury.
The following mounting installations are covered in this
manual. Identify the supplied mounting kit (page 6),
locate the appropriate installation within this manual.
• I-Beam Mounting Kit (page 7)
• Steel Truss Mounting Kit (page 7-8)
• Wood Beam Mounting Kit (page 8-9)
• Z-Purlin Mounting Kit (page 9)
®
• Unistrut
Mounting Kit (by others, page 9)
I-Beam Mounting Kit
(For Flanges up to 10 in. Wide)
Components required from Bag # 915428:
• I-Beam Clamping Plate (2)
• I-Beam Clamping Plate Shim (2)
• 1/2 in. – 13 x 21/2 in. Grade 8 Hex Bolt (4)
• 1/2 in. – 13 Grade 8 Nylon Locknut (4)
• 1/2 in. Washer (8)
Hardware/Tools Needed (Not Included):
• Torque Wrench
• 3/4 in. Socket and Ratchet
• 3/4 in. Wrench
1. Using appropriate lifting equipment, raise the
downtube and mount assembly until the universal
mounting plate is positioned on the bottom of the
I-beam.
2. Using the universal mounting plate as a guide,
identify the appropriate set of mounting slots to
use for installation. The universal mounting plate
can accommodate I-beams with a flange width up
to 10 in. and a web thickness up to 23/4 in.
3. Attach (1) I-beam clamping plate shim and (1)
I-beam clamping plate to the universal mounting
plate using (2) 1/2 in. – 13 x 21/2 in. grade 8 hex
bolts, (4) 1/2 in. washers, and (2) 1/2 in. – 13 grade
8 nylon locknuts. Hook the I-beam clamping plate
onto one side of the I-beam and tighten hardware
until the universal mounting plate is snug against
the beam but can still be moved (approximately
1/4 in. of the bolt threads exposed below the nylon
locknut).
®
1/2 in. - 13 X 2-1/2 in. GRADE 8 HEX BOLT
STEEL BEAM
4. Attach the opposing I-beam clamp plate shim and
I-beam clamp plate on to the universal mounting
plate and I-beam. Hand tighten hardware.
5. Center the universal mounting plate under the
I-beam. Ensure the I-beam clamp plates have
maximum engagement on both sides and tighten
hardware evenly to 45 ft∙lbf (61.0 N∙m).
6. Turn to page 10 to continue with Motor/Hub to
Downtube Installation.
Steel Truss Mounting Kit
Components required from Bag # 915429:
• Square Washer Plate (4)
• 1/2 in. – 13 x 11/2 in. Grade 8 Hex Bolt (4)
• 1/2 in. – 13 Grade 8 Nylon Locknut (8)
• 1/2 in. Washer (16)
Hardware/Tools Needed (Not Included):
• Structural Steel Angles (2)
• 1/2 in. – 13 Grade 8 Hex Bolt (4), length determined
by truss and steel angle material thickness
• Torque Wrench
• 3/4 in. Socket and Wrench
• 3/4 in. Wrench
• Drill and 9/16 in. Drill Bit
1. Size structural steel angles (by others) to fit within
steel trusses/bar joists. Size of steel angle to be
determined by structural engineer.
2. Mount structural steel angles to steel trusses/bar
joists using (4) grade 8, 1/2 in. – 13 bolts (by others
to accommodate varying material thickness), and
supplied (8) 1/2 in. washers, (4) square washer
plates, and (4) 1/2 in. – 13 nylon locknuts. Note
that the hardware should be installed through
the gap in the bottom chord of the steel trusses/
bar joists (reference drawing on page 8). Torque
hardware to 80 ft∙lbf (108.5 N∙m).
High Volume, Low Speed Ceiling Fans
TORQUE TO 45 FT LBF
(61.0 N m)
I-BEAM CLAMPING PLATE
I-BEAM CLAMPING PLATE SHIM
UNIVERSAL MOUNTING PLATE
1/2 in. WASHER
1/2 in. - 13 GRADE 8 NYLON LOCKNUT
DOWNTUBE & MOUNT ASSEMBLY
7