Greenheck DS-M Installation, Operation And Maintenance Manual page 14

High volume, low speed ceiling fans
Table of Contents

Advertisement

®
Gripple
Hardware (Optional)
Components required from Bag # 915067:
®
• No. 4 Gripple
Connector (1)
Hardware/Tools (Not Included):
• 1/16 in. Allen Wrench (optional)
• Cable Cutters (optional)
1. From the top of the downtube, pull the safety retention cable until the cable is taut inside the downtube.
2. Insert the loose end of the safety cable into the No. 4 Gripple connector. Note that the cable will only feed
through the Gripple connector in one direction (marked on the Gripple connector with an arrow).
3. Slide the No. 4 Gripple connector down the safety cable until it is located near the opening at the top of the
downtube.
4. Wrap the loose end of the safety cable around the mounting structure. Do not allow the cable to come in
contact with any sharp edges.
5. Insert the loose end of the safety cable into the open hole of the No. 4 Gripple connector. Note that the cable
will only feed through the Gripple connector in one direction (marked on the Gripple connector with an arrow).
6. Pull the loose end of the safety cable through the Gripple connector to tighten the cable. The cable should be
pulled taut, leaving only a small amount of slack in the cable to ensure proper functioning.
7. Cut or organize excess safety cable to ensure it does not interfere with fan rotation.
NOTE: If necessary, the safety cable can be loosened by inserting the long end of a 1/16 in. allen wrench into either
of the pin holes on the No. 4 Gripple connector and pulling the cable in the opposite direction of the arrow marked
on the Gripple connector.
DOWNTUBE SAFETY CABLE
14
High Volume, Low Speed Ceiling Fans
DOWNTUBE SAFETY CABLE
NO. 4 GRIPPLE
DOWNTUBE & MOUNT ASSEMBLY
®