Neue NDIH 1L949-80 User Manual page 42

Table of Contents

Advertisement

Troubleshooting
Error codes on the display
Problem
All LED lights
flash once every 3s
All LED lights
flash 3 times every
3s
All other Alarmcodes:
1. Note Alarmcode
2. Contact Service ; refer to CUSTOMER SERVICE
40
Possible cause
Water tap is closed.
Water inlet hose has a kink or
a bend.
In case of aqua-stop system:
water protection is triggered;
the marker (C) is red.
Filter in the water inlet hose
is clogged.
Water inlet is clogged.
Water pressure is too low.
Anti- flood device is on:
• There are water leakages in
the appliance.
• The water inlet valve is
open and blocked.
• The drainage is blocked.
Possible solution
Open the water tap.
Note: Whenever Error is
s o l v e d s w i t c h o f f t h e
appliance and restart the
programm.
Make sure that the position of
the hose is correct.
The hose must be replaced.
Clean the filter at the inlet
hose connections at tap and
the rear of the appliance.
Check water flow from tap.
Contact your local water
authority.
1.Close the water tap.
2.Disconnect appliance from
power supply.
3.Contact Service.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents