Product Use - Gavita Pro 1000e Manual

380-400v
Hide thumbs Also See for Pro 1000e:
Table of Contents

Advertisement

Pro
Pro
line
line
8

Product use

Warning! Never use the luminaire without a lamp or reflector!
6
Warning! Always wait 20 - 30 minutes for the reflector to cool down!
6
Caution! Before you dim or boost your HPS lamp, make sure that you run it at nominal value (100%) for at least 100
1
hours to stabilize the lamp. Failing to do so may lead to sub-optimal light levels and premature end of life failure of
your lamp.
9
Troubleshooting using the status LED
The multi colour status LED provides information on the condition of the controller and the lamp. Consult chapters 9.1 and
9.2 to interpret the status LED. LED signals are represented by colored dots.
All operating modes include GREEN;
All warning codes include RED;
All history codes (except the ignition code) include ORANGE;
WARNINGS and history codes overrule operating mode display.
9.1
Status indications
Status LED message
Status luminaire
Description
No power / off
The luminaire is not connected to
the mains or the power is off
Ballast stand-by
Luminaire is connected to the
mains and to a controller. Output
of ballast is off.
Ballast on
Luminaire is connected to the
mains and to a controller. Output
of ballast is on
Luminaire is igniting the
Luminaire is trying to restart the
lamp
lamp
Check power
No action required. When lamp
doesn't start: lamp too hot,
defect or not properly connected
(remote). Disconnect, check
power cord and connections.
9
Action / Solution