7.4
Preparation for use with a controller
Using a daisy chain setup, a maximum of 100 luminaires can be connected to one controller. Up to 500 luminaires per daisy
chain can be connected when using splitters. See section 7.5 and 7.6 of this manual and the manual of the controller.
1. Take the unstripped black interconnect cable.
2. Cut the cable (supplied with controller) to the desired length and strip both ends using a crimp tool (6).
3. Insert the cable end in the RJ25 connectors (7) and use the crimp tool to finish the assembly.
4. Mount ferrite cores (item A mentioned in 7.3) to both cable ends close to the RJ25 connectors (8).
6
7.5
Connecting up to 100 luminaires
Using a setup with daisy chained splitters, up to 100 luminaires on RS1, EL1 or EL2 can be connected as shown in fig. 10.
1. Remove the dummy from the input port on the first luminaire (9).
Note: Keep the dummy in a safe place! The dummy is necessary to operate the luminaire in standalone mode.
2
2. Use the black controller cable (item is supplied with controller) to connect the controller input port on the first
luminaire (10A).
3. Remove the dummy from the input port on the second luminaire.
4. Use a grey 6P6C modular jack interconnect cable (item C) with integrated ferrite cores to connect the output port of
the first luminaire to the input port of the second luminaire (10B). The indicator light will blink when the connection is
successful.
5. Repeat these steps to connect up to 100 luminaires (10C).
Warning! Ensure the power cord and the controller cables do not touch any of the reflectors.
6
9
7.6
Connecting up to 500 or 1000 luminaires
Using a setup with daisy chained splitters, up to 500 luminaires on RS1 or EL1 and 1000 luminaires on EL2 (over two
channels) can be connected as shown in fig. 11.
1. Use the black controller cable (item comes with the controller) to connect the primary channel of the controller to the
input port of the first splitter (11A).
2. Remove the dummy from the input port of the luminaires (9).
Note: Keep the dummy in a safe place! The dummy is necessary to operate the luminaire in standalone mode.
2
3. Use a grey 6PC6 modular jack interconnect cable (item C) to connect the output port of the splitter to the input port of
the first luminaire (11C).
7
A
10
6
8
B
1
2
C
max. 100