7.0 - PROGRAMMING

Only expert users should modify these settings to avoid malfunctions of the parking
!
The display will indicate:
FS: Factory Setting, standard adjustment , "Factory parameters".
CS: Custom Setting, user-chosen adjustment, "Custom Parameters".
To activate the programming procedure proceed as follows:
Press one of the two push-buttons on the control unit and keep it pressed for at least two seconds;
the system will activate and enter in the programming mode.
Press the left push-button to go to the previous
parameter.
When the parameter you want to modify is displayed, press one of the push-buttons and keep it
pressed until the display starts to blink; at this point you can modify the parameter.
Press the left push-button to decrease the value
of the parameter.
Press one of the two
push-buttons
on the control unit and keep it pressed for at least two seconds
to register the value.
The display will stop blinking and the selected parameter will be displayed.
If no button is pressed within10 seconds, the system will exit the programming mode.
Press the two push-buttons on the control unit and keep them pressed for more than
!
two seconds to reset all the factory settings (FS).
PAGE 08 - INSALLER MANUAL
system.
Press the right push-button to go to the next
parameter.
Press the right push-button to increase the value
of the parameter.

8.0 - SETTING OF PARAMETERS

Nr.
PARAMETERS
01
Volume of buzzer
03
Detection range of front corner sensors
07
STOP zone of front corner sensors
11
Number of speed signal pulses
12
Delay of front sensors deactivation
15
Service display (testing)
16
Continuous detection
Ref.1
: 0 = deactivated, 1 = low, 2 = high.
Ref.2
:
by setting "1", the system activates also when reverse gear is engaged. For connections and
operation see par. 6.0 and
3.3.
Ref.3
: by setting "00", the system is activated every time ignition is turned on; to deactivate, press the
push-button with the LED. Press again, to reengage the sensors.
Ref.4
: 0 = not activated, 1 = distance from the closest front obstacle, 3 = vehicle speed (in km/h, for
programming refer to parameter 11).
Rif.5:
0 = deactivated, 1 = activated.
!
Press one of the two push-buttons on the control unit to enter in the programming mode.
!
Select parameter "15" (see "Setting of parameters").
!
Press and keep pressed one of the two push-buttons and select test (1 for testing the sensors or 3
for detection speed).
!
Press and keep pressed one of the two push-buttons; the display will show "--".
!
Proceed with the sensors test; the system will indicate the value detected in real time.
!
Reprogram setting of parameter to "0".
!
Press one of the two push-buttons and keep it pressed until the previously selected parameter is
displayed (15).
!
The system will automatically exit the programming mode 10 seconds after the push-button has
been pressed.
10.0 - WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT
(WEEE) DIRECTIVE
The present device does not fall within the scope of Directive 2002/96/EC on Waste Electrical and
Electronic Equipment (WEEE) as specified in art. 2.1 of L.D. no. 151 of 25/07/2005.
RANGE
0, 1, 2 (
Ref.1
)
From 50 to 95 cm
From 25 to 50 cm
From 1 to 99 (
Ref.2
)
0 or from 10 to 60 sec. (
Ref.3
)
0, 1, 3 (
Ref.4
)
0, 1 (
Ref.5
)

9.0 - TESTING

INSALLER MANUAL - PAGE 09
SETTING
2
55
25
3
00
0
0