Safety Precautions; Installation Diagram - Sharp AE-X4M30PU Installation Manual

Multi split type room air conditioner
Hide thumbs Also See for AE-X4M30PU:
Table of Contents

Advertisement

Available languages

Available languages

Carefully read and follow these instructions for smooth and trouble-free installation.
ENGLISH
This manual describes the installation of outdoor unit only
For the installation of the indoor unit, see the installation manual accompanying indoor unit.

SAFETY PRECAUTIONS

• Installation must be made in accordance with the installation
manual by qualifi ed service personnel.
Incorrect work will cause electric shock, water leak, fi re.
• Be sure to use the attached accessories parts and specifi ed
parts for installation.
Use of other parts will cause electric shock, water leak, fi re, the unit
falling.
• The appliance shall be installed and wired in accordance with
National Electrical Code and by qualifi ed personnel only.
Wrong connection can cause overheating or fi re.
• After installation has complete, check that there is no leakage
of refrigerant gas.
If the refrigerant gas contact with fi re, it may generate toxic gas.
• Ventilate the room if refrigerant gas leaks during installation.
If the refrigerant gas contact with fi re, it may generate toxic gas.
• Use the specifi ed electrical cable.
Make sure the cable is secured in place and that the terminals are
free of any excess force from the cable. Otherwise overheating or
fi re may result.
• Form the cable so that the control box cover, the cord holder
and cable holder are not loose.
Otherwise overheating, fi re or electric shock may result.
ACCESSORIES
ITEMS
1 Installation Manual
2 Base pan cap
NOTES ON LOCATIONS
1. Place the outdoor unit on a stable base.
2. Provided suffi cient space around the unit. It should also be
well ventilated.
3. The unit should not be exposed to strong wind nor splashed
with rain water.
4. Water drain from the unit should be let out without problem.
Lay a drain hose if required. In cold regions, installation of
the drain pipe is not advisable as freezing could result.
5. Keep TV sets, Radio and other related electronic appliances
at least 3.3 feet away from the unit.
6. Avoid locations exposed to machine oil vapor, salty air (facing
the seashore, for example), hot spring vapor sulfur gas, etc.
Such location can cause breakdown.
7. Avoid locations exposed to muddy water (along a road, for
example) or where the unit can be tampered with.
8. Select a location where the outgoing air or operating noise
cannot annoy others.
9. Keep the air outlet opening free of any obstacle. This could
affect the performance of the unit and create loud noises.
10.For colder climate areas, install the unit in a location not
affected by snow or ice falls (example: roof houses). Unit
should be installed minimum 10 inches (25 cm) from ground
level or follow your country's average snowfall accumulation.
PIPING
Max. piping
Max. total piping length of all
length:A
unit
2 units:164 ft (50 m)
82 ft (25 m)
3 units, 4 units: 230 ft (70 m)
1. Standard piping length is 25 ft (7.6 m).
2. When the outdoor unit is placed at a higher level than the indoor unit, provide a trap near the hose's lead-in port.
Use the refrigerant pipes shown in the table below.
Pipe size
Liquid side
1/4" (ø 6.35 mm)
3/8" (ø 9.52 mm)
Gas side
1/2" (ø 12.7 mm)
• The thermal insulation should cover both the gas and liquid pipes.
IM_A3AEX4M3PU(B434)_EN+FR+ES.indb EN-1
IM_A3AEX4M3PU(B434)_EN+FR+ES.indb EN-1
Q'ty
ITEMS
3 Drain tray
1
4 Drain joint
4
• Provide as much installation space as possible for
Min. piping
Max. height difference:
length:A
B
C
49 ft
49 ft
10 ft (3 m)
(15 m)
(15 m)
Pipe thickness
Thermal insulation
Thickness: 0.24 inch (6 mm) or thicker
0.03 inch (0.8 mm)
Material: Polyethylene foam
EN-1
• Tighten the fl are nut with a torque wrench according to the
specifi ed method.
If the fl are nut is tightened too hard, the fl are nut may be broken after a
long time and cause refrigerant gas leakage.
• When installing the unit, take care not to enter air substance other
than the specifi ed refrigerant(R410A) in the refrigerant cycle.
Otherwise, it will cause burst and injury as a result of abnormal high
pressure in the refrigerant cycle.
• Be sure to connect the refrigerant pipe before running the
compressor.
Otherwise, it will cause burst and injury as a result of abnormal high
pressure in the refrigerant cycle.
• Ground the unit.
Incomplete ground may cause electrical shock.
• Install a Ground Fault Interrupt (GFI) circuit breaker depending on
the installation location of the unit (such as highly humid areas).
If GFI breaker is not installed, it may cause electric shock.
• Arrange the drain hose to ensure smooth drainage.
Insuffi cient drainage may cause wetting of the room, furniture etc.
• This room air conditioner uses refrigerant R410A.
Use the pipe, fl are nut and tools exclusively for R410A.
Q'ty
5 Reducer (1/2"
1
1
Seal Ring

INSTALLATION DIAGRAM

1 ft (300
mm)
or more
3.3 ft (1000
mm) or more
effi cient air-conditioning.
Chargeless Max.
Additional refrigerant
piping length
D
49 ft
164 ft (50 m)
0.16 oz/ft (15 g/m)
(15 m)
ITEMS
Q'ty
3/8")
Joint
2
Flare nut
1 ft (300
mm) or more
Coating tape
(Commercially available)
1.3 ft (400
mm) or more
For installation work
A
B
D
C
Trap