  • Page 1 Split Type Inverter Room Air Conditioner OPERATION MANUAL MODELS AY-X24LCJ AE-X24LCJ Thank you for choosing a SHARP air conditioner. Please read this manual thoroughly before using your air conditioner and keep it for future reference.
  • Page 3 and cleaning Specifications NOTE: The figures in this manual may be different to the actual product. that should be prevented. that Collection of such waste should be separated for special treatment as required by local regulations.
  • Page 5 To change the airflow direction, adjust the vertical and lateral air flow direction by using the , pl ease ref er the mat ter to remote control. a qualified air conditioner contractor. objects Don’t expose animals and plants directly to the output air flow as it may have a detrimental effect on them.
  • Page 6 Air conditioners absorb heat in the room and transmits it to the outdoor unit, so that indoor ambient temperatures are decreased. Its cooling capacity will increase or decrease according to outdoor ambient temperature. If the unit is running in COOL mode and in low ambient temperature, frost may be formed on the heat exchanger.
  • Page 7: Name And Function Of Each Part

    Na me and function of each part...
  • Page 8 Note: Be sure that there are no obstructions between receiver and remote control; Don't drop or throw the remote control; Don't spill any liquid on the remote control; Don't leave remote control directly in sunlight or hot environments. Pres s this button to turn Sleep mode on or off.
  • Page 9 Name and function of wireless remote control Some buttons on this control are not applicable to this unit. Preset temperature is increased by pressing this button. Continuously pressing and holding for 2 seconds changes the temperature rapidly. Preset temperature is decreased by pressing this button.
  • Page 10 Some buttons on this control are not applicable to this unit. Press this button to select Timer On setting. Pressing the + or - button during the first 5 seconds adjusts the time value by one minute each time pressed. Holding the + or - button down for more than 2 seconds changes the time rapidly.
  • Page 11 Press On /Off button to start or stop operation. to switch On or Off the display on the main unit. odels to switch BLOW the fan will con tinu e to bl ow af ter the un it is stop pe d to rem ove BLOW BLOW BLOW...
  • Page 12 o set the guide louvre to a desired position, press Swing Up and Down button continuously for more than 2 seconds and hold until desired position is achieved. Releasing the button now stops the swinging at the desired position. After Swing Up and Down mode is switched on, pressing the button again within 2 seconds circulates between the various settings.
  • Page 13 on the main unit. Operation will be in Auto Run mode and the temperature setting or fan speed cannot be changed. To operate: Press the AUTO/STOP button and the unit will enter into AUTO RUN mode. The microcomputer will monitor the room temperature to select the (COOL, HEAT, FAN) mode automatically, to obtain the comfortable effect.
  • Page 14: Care And Cleaning

    Care and Cleaning at the circuit breaker to prevent the risk of electric shock. pour or spray liquids directly onto the indoor or outdoor units for cleaning, to prevent risk of electric shock. Only wipe the Rotate the front panel upwards in the direction of the arrow.
  • Page 15 Care and Cleaning Removing Rotate the front panel upwards in the direction of the arrow. Pull the air filter downwards and remove from the unit. water temperature should be and leave to dry naturally in a shady location. Never dry it with a heater or open flame, as fire or deformation may occur.
  • Page 16 The air conditioner is not user serviceable. if attempt to If a bad smell has been accumulated from the environment, clean the air filter. If smells persist, contact your Approved Service Centre to arrange cleaning. fluid gurgling noises. This is not a fault - it is the sound of flowi ng refrigerant.
  • Page 17 will Has the circuit breaker device tripped off? Have the wiring or connections been damaged?Please report to an authorised air conditioner contractor. Is the fan other working Check that there is no magnetic or electrical interference near the main unit that may be affecting the operation of the controller.
  • Page 18 flow is stopped fros t can be for med on the outdoor heat exchanger. The unit will automatically defrost and the indoor unit will stop blowing air for 3-12 mins. During defrost operation, water or vapour may be emitted. ,disco nnect from the power supply, and report to an authorised air conditioner contractor in the following situations.
  • Page 19 The unit mus t only be installed by authorised air conditioner contractors according to mun icipal or governmen t regulations and in compl iance wi th this man ual. The unit should be installed with a dedicated electrical circuit, and a circuit breaker should be fitted in accordance with regulations.
  • Page 20 A dedicated power supply circuit should be used, in accordance with local electrical safety regulations. The product should be installed by a licenced air conditioning contractor in accordance with AS/NZS3000 and your electrical supplier's rules. A circuit breaker should be installed. WARNING: inadequate or incorrect electrical connections may cause electrocution or fire.
  • Page 21 Height...
  • Page 22: Installing The Indoor Unit

    Installing the indoor unit is at the lef t, the righ t si de sh ou ld be slightly higher to allow drainage. Spirit Level proper Drainage hoses passing through indoor areas should be wrapped with insulation material. by rotating upwards. Remove the electrical connection cover plate and screw.
  • Page 23 Installing the indoor unit All interconnecting wiring between indoor and outdoor unit must be performed by a licenced electrical contractor in accordance with AS/NZS3000. unit to screws adequately to prevent loosening. Ensure the electrical connections are properly earthed to prevent electrical shocks. Ensure all wiring connections are secure and the cover plates are reinstalled properly.
  • Page 24: Installing The Outdoor Unit

    Installing the Outdoor Unit Remove electrical connection access plate (either right hand side or front) from the outdoor unit. Replace access plate (either right hand side or front) on the outdoor unit. Incorrect unit failure. has been fitted,...
  • Page 25 Installing the Outdoor Unit soapy gas detection are leaking. Outdoor attach satisfactorily.
  • Page 26 satisfactory to the product. product. Are the inlet and outlet air openings blocked? Is the quantity of gas charge sufficient may be for the length of pipe run? insufficient.
  • Page 27: Specifications

    Specifications Model AY-X24LCJ;AE-X24LCJ Function COOLING HEATING AC Rated Voltage (V) 220-240 V~ Frequency (Hz) Total Capacity (W) (High/ Standard): 6500/2250 7200/1800 Total Capacity (Btu/h) (High/ Standard): 22200/7700 24550/6150 Power Input (W) (High/ Standard/Low) 2600/2000/550 3100/1990/500 Rated Input (W) (High/ Standard) 2600/2000 3110/1990 Rated Current (A) (High/ Standard)
  • Page 28 Model of Outdoor Unit AE-X24LCJ Compressor Manufacturer/trademark SANYO Compressor Model C-6RZ146H1A Compressor Type Twin Rotary L.R.A. (A) Compressor RLA(A) Compressor Power Input(W) 1640 Overload Protector 1NT11L-3979 Throttling Method Capillary throttling Starting Method Transducer starting Working Temp Range (℃) -15℃≤T≤46℃ Condenser Aluminum fin-copper tube Φ9.52 Pipe Diameter (mm)
  • Page 30 SHARP APPROVED SERVICE CENTRE VISIT OUR WEBSITE AT www.sharp.net.au OR CALL SHARP CUSTOMER CARE 1300 135 022 (LOCAL CALL COST APPLY WITHIN AUSTRALIA) SHARP CORPORATION OF AUSTRALIA PTY LTD SHARP FOR LOCATION ENQUIRIES WITHIN NEW ZEALAND REGARDING YOUR LOCAL SHARP APPROVED SERVICE CENTRE VISIT OUR WEBSITE AT www.sharp.net.nz...