5.5.3

Removing a pluggable transceiver (SFP)

Notes on deinstallation
Risk of burns due to the high temperatures of the pluggable transceiver
The pluggable transceivers can be plugged and pulled during operation. Leave the transceiver
to cool down as much as possible.
Procedure
Follow the steps below to remove a pluggable transceiver:
1. Remove the connecting cable of the pluggable transceiver.
2. Open the clip of the pluggable trabsceiver.
3. Remove the pluggable transceiver from the pluggable transceiver slot.
Note
Do not use force
It must be possible to remove the pluggable transceiver easily and without applying any
force.
4. Close the pluggable transceiver slot with a sealing plug.
SCALANCE XR-300WG
Operating Instructions, 03/2021, C79000-G8976-C454-07
CAUTION
5.5 Inserting and removing pluggable transceivers
Installation
47