Siemens SIMATIC NET SCALANCE XR-300WG Operating Instructions Manual page 14

Industrial ethernet switches
Hide thumbs Also See for SIMATIC NET SCALANCE XR-300WG:
Table of Contents

Advertisement

Recommendations on network security
Available protocols
The following list provides you with an overview of the open protocol ports.
The table includes the following columns:
• Protocol
• Port
• Default port status
– Open
– Closed
• Configurable port
– ✓
– --
• Authentication
Specifies whether the communication partner is authenticated.
• Encryption
Specifies whether or not the transfer is encrypted.
List of available protocols (local access via a local network)
The following is a list of all available protocols and their ports through which the device can be
accessed.
Protocol
Protocol/
Port number
DHCPv4 Server
UDP/67
DHCPv4 Client
UDP/68
Discard
TCP/9
Echo IP
UPD/TCP/9
EtherNet/IP
TCP/44818
UDP/2222
UDP/44818
HTTP
TCP/80
HTTPS
TCP/443
Kerberos
TCP/464
NTP
UDP/123
SNTP
NTP (secure)
UDP/123
14
The factory setting of the port is "Open".
The factory setting of the port is "Closed".
The port status can be changed.
The port status cannot be changed.
Default port sta‐
tus
Closed
Open
Open, filtered
Open
Closed
(Open with
EtherNetIP var‐
iants)
Open
Open
Open, filtered
Closed
Closed
Configurable
Authentication
port
No
No
--
No
--
No
No
Yes
Yes
--
No
No
Yes
Operating Instructions, 03/2021, C79000-G8976-C454-07
Encryption
No
No
No
No
No
No
Yes
No
No
No
SCALANCE XR-300WG