Installing and removing
5.6 Disassembly
5.5.3

Removing a pluggable transceiver (SFP/SFP+)

Notes on deinstallation
Risk of burns due to the high temperatures of the pluggable transceiver
The pluggable transceivers can be plugged and pulled during operation. Leave the transceiver
to cool down.
Procedure
Follow the steps below to remove a pluggable transceiver:
1. Remove the connecting cable of the pluggable transceiver.
2. Open the clip of the pluggable trabsceiver.
3. Remove the pluggable transceiver from the pluggable transceiver slot.
Note
Do not use force
It must be possible to remove the pluggable transceiver easily and without applying any
force.
4. Close the pluggable transceiver slot with a sealing plug.
5.6

Disassembly

Improper disassembly
Improper disassembly may result in a risk of explosion in hazardous areas.
For proper disassembly, observe the following:
• Before starting work, ensure that the electricity is switched off.
• Secure remaining connections so that no damage can occur as a result of disassembly if the
54
CAUTION
WARNING
system is accidentally started up.
Operating Instructions, 03/2023, C79000-G8976-C586-02