ALH
Characteristics / Technical Specifications
since 1928
9 | CHARACTERISTICS AND TECHNICAL SPECIFICATIONS
9 .1 - PERFORMANCE CURVES
0.25 (0.33)
ALH05 (3 lobes)
0.18 (0.25)
Continuous 24/24h
Pump speed: (Rpm)
10
20
Flow: l/h (gph)
3.4 (0.9)
6.8 (1.8)
10.2 (2.7)
1 rpm = 0.34 L/h = 0.090 gph
1 rev = 0.0057 L = 0.0015 gal
0.55 (0.75)
ALH10
0.37 (0.50)
0.25 (0.33)
Continuous 24/24h
Pump speed: (Rpm)
10
20
30
40
50
Flow: l/h (gph)
15
30
45
60
75
(4)
(7.9)
(11.9)
(15.9)
(19.8)
1 rpm = 1.50 L/h = 0.396 gph
1 rev = 0.0250 L = 0.0066 gal
0.55 (0.75)
ALH 15 (3 lobes)
0.37 (0.50)
0.25 (0.33)
Continuous 24/24h
Pump speed: (Rpm)
10
20
30
40
50
Flow: l/h (gpm)
35
70
105
140
175
(9.2)
(18.5)
(27.7)
(37)
(46.2)
1 rpm = 3.50 L/h = 0.925 gph
1 rev = 0.0583 L = 0.0154 gal
*Intermittent use : minimum one hour stop after 2 hours run / *Occasional use : maximum one hour a day
26 albinpump@irco.com
Albinpump.com
40°C (104°F)
50°C (122°F)
60°C (140°F)
70°C (158°F)
80°C (176°F)
Intermittent*
Occasional*
30
40
50
60
13.6 (3.6)
16.9 (4.5)
20.4 (5.4)
*Intermittent use : minimum one hour stop after 2 hours run / *Occasional use : maximum one hour a day
40°C (104°F)
50°C (122°F)
60°C (140°F)
70°C (158°F)
80°C (176°F)
Intermittent*
Occasional*
60
70
80
90
100
110
120
90
105
120
135
150
165
180
(23.8)
(27.7)
(31.7)
(35.7)
(39.6)
(43.6)
(47.6)
40°C (104°F)
50°C (122°F)
60°C (140°F)
70°C (158°F)
80°C (176°F)
Intermittent*
Occasional*
60
70
80
90
100
110
120
210
245
280
315
350
385
420
(55.5)
(64.7)
(74)
(83.2)
(92.5)
(101.7)
(111)
Albin Pump ALH Instruction Manual
0.55 (0.75)
ALH10 (3 lobes)
0.37 (0.50)
0.25 (0.33)
Continuous 24/24h
Pump speed: (Rpm)
10
20
30
Flow: l/h (gph)
10 (2.6)
20 (5.3)
30 (7.9)
1 rpm = 1.00 L/h = 0.264 gph
1 rev = 0.0167 L = 0.0044 gal
0.55 (0.75)
ALH15
0.37 (0.50)
0.25 (0.33)
Continuous 24/24h
Pump speed: (Rpm)
10
20
30
40
50
60
Flow: l/h (gph)
50
100
150
200
250
300
(13.2)
(26.4)
(39.6)
(52.8)
(66.1)
(79.3)
1 rpm = 5.00 L/h = 1.321 gph
1 rev = 0.0833 L = 0.0220 gal
0.55 (0.75)
ALH20 (3 lobes)
0.37 (0.50)
0.25 (0.33)
Continuous 24/24h
Pump speed: (Rpm)
10
20
30
40
50
60
Flow: l/h (gpm)
55
110
165
220
275
330
(14.5)
(29.1)
(43.6)
(58.1)
(72.7)
(87.2)
1 rpm = 5.50 L/h = 1.453 gph
1 rev = 0.091 L = 0.024 gal
40°C (104°F)
50°C (122°F)
60°C (140°F)
70°C (158°F)
80°C (176°F)
Intermittent*
Occasional*
40
50
60
70
40 (10.6)
50 (13.2)
60 (15.9)
70 (18.5)
40°C (104°F)
50°C (122°F)
60°C (140°F)
70°C (158°F)
80°C (176°F)
Intermittent*
Occasional*
70
80
90
100
110
120
350
400
450
500
550
600
(92.5)
(105.7)
(118.9)
(132.1)
(145.3)
(158.5)
40°C (104°F)
50°C (122°F)
60°C (140°F)
70°C (158°F)
80°C (176°F)
Intermittent*
Occasional*
70
80
90
100
110
120
385
440
495
550
605
670
(101.7)
(116.2)
(130.8)
(145.3)
(159.8)
(177)
Need help?
Do you have a question about the ALH and is the answer not in the manual?