4.3.3
Checking RF communication with the HR80 radiator controller
The evotouch controller will send and receive test signals to and from the assigned HR80 to test the signal strength.
evotouch controller receiving test messages from the HR80
f
Separate HR80 operating unit from coupling module
(see instructions HR80).
f
Turn the adjustment dial until
the display.
f
Turn the adjustment dial two full rotations (720°)
further.
TesT is displayed and the HR80 transmits the test
message to the evotouch controller.
i
The signal strength can be EXCELLENT, GOOD, POOR
or not received
HR80 receiving test signal from the evotouch controller
f
While
TesT is displayed, press the bind button (1) on
the HR80.
The HR80 radiator controller is ready to receive the
test message from the evotouch controller.
The first two digits in the display indicate the number
of received test messages, and the right-hand digit
indicates the field strength
1 = sufficient field strength
5 = very good field strength
Deactivating the RF communication check
f
Press the bind button (1) on the HR80 for 5 seconds.
or
f
Wait 5 minutes.
or
f
Remove and re-insert the batteries of the HR80.
Completing configuration
f
Press the NEXT button and in the following screen press the DONE button.
Configuration of the HR80 radiator controller is completed.