Set Bypass Percentages - Bunn Dual SH Installation And Operating Manual

With smart funnel
Table of Contents

Advertisement

PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
% BYPASS
This function allows adjustment of the amount of
water that bypasses the grounds. The number signi-
fies the percentage of the brew volume which does not
flow over the coffee grounds.
Modifying recipes - bypass percentages:
Range: 0% to 90% for all three batch sizes
NOTE: If the brewer is already in the % BYPASS
screen, it is not necessary to follow steps 1 through 6
in this section, but proceed directly to step 7.
1. Press and hold the ® pad until the display reads
SET NEW RECIPES. Release the ® pad. Press the
® until the display reads REVIEW RECIPES.
2. Press YES to proceed. The display should now
read NO-NAME LEFT, along with MODIFY, SHOW
and NEXT.
3. Press and release NEXT to advance to the desired
coffee name to be modified.
4. Press and release MODIFY. The display should
read BREW OZ.
5. Press and release DONE. The display should read
3 BATCHES DONE?.
6. Press and release YES. The display should now
read % BYPASS, and a batch light will be blinking.
Press and release the batch size to be modified.
7. Using (-) and (+) set the amount of bypass water
(percentage) to be dispensed around the grounds
for that particular batch size.
8. When finished, press another batch size and re-
peat step #7 for each batch to be modified.
9. When finished setting all batch sizes, press DONE.
The display should read 3 BATCHES DONE?
10. If they are not correct, press and release NO to
return to the % BYPASS setup screen.
11. If the 3 batch sizes are correct, press YES. This will
advance to SET PULSE BREW. Another alternative
is to press either of the
BYPASS setup and return to the MAIN SCREEN.
Page 19
pads to exit the %
P2292
29877 080301