Download Print this page
NEUTRIK NAC3FX-W-TOP Application & Assembly Instruction

NEUTRIK NAC3FX-W-TOP Application & Assembly Instruction

Advertisement

Quick Links

R
A. APPLICATION INSTRUCTION
Application:
The power
CON
IEC 60320, VDE
It serves to supply power to
To be installed by qualified person only.
CONNECTOR ASSIGNMENT:
APPLIANCE INLET
NAC3MPX-TOP
NAC3MPX-WOT-TOP
Power IN
NAC3FX-W-TOP
(Connector)
power
CON
TRUE1 TOP line is full backward compatible with the preceding power
Approval based:
Rating:
Cable Type:
Strain Relief:
Cable O.D.:
UL50E environmental rating
Enclosure Type 4 when mated with attachment plug NAC3MX-W-TOP or mated with appliance inlet
NAC3MPX*-TOP with sealing cover SCNAC-MPX and NAC3PX-TOP with sealing cover SCNAC-PX.
B. ASSEMBLY INSTRUCTION
A
Insert cable into the bushing and housing.
Note: "Apply cable pulling
lubricant to cable jacket."
C
Place chuck over the
cable.
D
Prepare cable as
shown.
BDA 541
800.638.6104 | www.covid.com
NAC3FX-W-TOP
TRUE1 system is certified as
0625.
It is intended for use as
an
appliance and from an appliance to other equipment.
APPLIANCE OUTLET
NAC3MX-W-TOP
(Plug connector)
VDE
EN 60320-1/EN60320-2-2
250 V ac / 16 A
H05VV-F3G 1.0 mm , Length max. 2 m
H05VV-F3G 1.5 - 2.5 mm
H07RN-F3G 1.5 mm
White chuck
6.0 - 12.0 mm
VDE (EN 60320-1/EN60320-2-2)
ASSEMBLY INSTRUCTION
|
power
CON
a
connector with breaking cap
an appliance coupler and interconnection coupler.
APPLIANCE INLET / OUTLET
u
NAC3FPX-TOP
NAC3FPX-WOT-TOP
NAC3FPX-ST-TOP
Power OUT
NAC3FX-W-TOP
(Connector)
UL
UL 498 / CSA C22.2 No. 182.3
250 V ac / 20 A
2
SJTOW, SJOOW 3 x 12 AWG
2
2
White chuck
6.0 - 12.0 mm
B
Separate the
housing from the
bushing (cable
remain in bushing)
C
Recommendation:
i
Wire Pulling Lubricant - LUB-I/0.95
from 3M
2 mm
0
[
0.787
"]
8 mm
[0.32"]
PE 23 mm
[
0.9
"]
UL (UL 498 / CSA C22.2 No. 182.3)
®
TRU 1
E TOP
ac
ity according
Combination
NAC3PX-TOP
Power IN
Power OUT
NAC3MX-W-TOP
(Plug connector)
CON
TRUE1 products.
TM
2 mm
0
[
0.787
"]
PE 23 mm
[
0.9
8 mm
[0.32"]
"]
Page 1

Advertisement

loading
Need help?

Need help?

Do you have a question about the NAC3FX-W-TOP and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for NEUTRIK NAC3FX-W-TOP

  • Page 1 ASSEMBLY INSTRUCTION NAC3FX-W-TOP power ® TRU 1 E TOP A. APPLICATION INSTRUCTION Application: The power TRUE1 system is certified as connector with breaking cap ity according IEC 60320, VDE 0625. It is intended for use as an appliance coupler and interconnection coupler.
  • Page 2 F: +91 22 26163 540 Vertriebs GmbH Draft. Nr.: BDA 541 Update: 11.07 .201 Data subject to change without prior notice. © NEUTRIK ® . NEUTRIK are registered trademark of NEUTRI AG. ® ALL RIGHTS RESERVED www.neutrik.com Page 2 800.638.6104 | www.covid.com...

This manual is also suitable for:

Powercon true1 top