Quick Links

R
A. OPERATING INSTRUCTION
Application:
The power
CON
TRUE1 system is certified as connector with breaking cap
60320, VDE
0625.
It is intended for use as
serves to supply power to
qualified person only.
Connector Assignment:
APPLIANCE INLET
NAC3MPX
Power IN
NAC3FX-W
(Connector)
Approval based:
Rating:
Cable Type:
Strain Relief:
Cable O.D.:
B. ASSEMBLY INSTRUCTION
A
Insert cable into the
bushing and housing.
Note: "Apply cable
pulling lubricant to
cable jacket."
C
Place
the
chuck over
the cable.
D
Prepare
the
cable as
shown.
BDA 380
All manuals and user guides at all-guides.com
ASSEMBLY INSTRUCTION
|
power
appliance couplers and interconnection couplers.
an
appliance and from an appliance to another equipment.
APPLIANCE OUTLET
Power OUT
NAC3MX-W
(Plug connector)
VDE
EN 60320-1/EN60320-2-2
250 V ac / 16 A
H05VV-F3G 1.0 mm , Length max. 2 m
2
2
H05VV-F3G 1.5 - 2.5 mm
2
H07RN-F3G 1.5 mm
White chuck
6.0 - 12.0 mm
B
C
2 mm
0
[
0.787
PE 23 mm
VDE (EN 60320-1/EN60320-2-2)
CON
TRU 1
E
APPLIANCE INLET - OUTLET
NAC3FPX
NAC3FPX-ST
Power IN
NAC3FX-W
(Connector)
UL
UL 498 / CSA C22.2 No. 182.3
250 V ac / 20 A
SJTOW, SJOOW 3 x 12 AWG
White chuck
6.0 - 12.0 mm
Separate the
housing from the
bushing (cable
remain in bushing)
"]
8 mm
[0.32"]
[
0.9
"]
UL (UL 498 / CSA C22.2 No. 182.3)
ac
ity according IEC
It
To be installed by
COMBINATION
NAC3PX
Power OUT
NAC3MX-W
(Plug connector)
2 mm
0
[
0.787
"]
8 mm
[0.32"]
PE 23 mm
[
0.9
"]
Page 1

Advertisement

loading
Need help?

Need help?

Do you have a question about the powerCON TRUE1 and is the answer not in the manual?

Questions and answers

Summary of Contents for NEUTRIK powerCON TRUE1

  • Page 1 All manuals and user guides at all-guides.com ASSEMBLY INSTRUCTION power TRU 1 A. OPERATING INSTRUCTION Application: The power TRUE1 system is certified as connector with breaking cap ity according IEC 60320, VDE 0625. It is intended for use as appliance couplers and interconnection couplers. serves to supply power to appliance and from an appliance to another equipment.
  • Page 2 +49 8131 / 280 890 +49 8131 280 830 91/982 05 43 424 +91 22 26163 540 Draft. Nr.: BDA Update: 13.07.2016 ® ® Data subject to change without prior notice. 201 © NEUTRIK . ALL RIGHTS RESERVED. NEUTRIK are registered trademark.

This manual is also suitable for:

Nac3mx-w