Adjustment Of The Optimum Exposure Setting In The Auto Mode - Minolta EP1054 General Instructions Manual

Hide thumbs Also See for EP1054:
Table of Contents

Advertisement

(3) Adjustment of the Optimum Exposure Setting in the Auto Mode

Important
• This adjustment must be made after the optimum exposure setting in the Manual Mode
has been adjusted.
NOTE
Pressing the Start Key lets the copier make the adjustment of optimum exposure setting.
During the adjustment, the Start Key is lit up orange. It turns to green as soon as the adjust-
ment is completed. (It takes about 5 sec. to make the adjustment.) The Full Size Key can be
used to alternately display on the Magnification Ratio Indicator either the adjusting value
(AE Sensor memory level) or the voltage value (AE Sensor output).
1. Place about five sheets of A3 or 11" × 17" paper on
the Original Glass and lower the Original Cover.
1139D015AA
2. On the control panel, press the Meter Count Key,
stop Key, 10-keys "0", 10-keys "0", stop Key, 10-
keys "0", 10-keys "1", 10-keys "1" and then "5" to
set the copier into the F5 Test Mode. (At this time,
the Multi-Copy Display shows "F5.")
1139D017CA
3. Press the Start Key to let the copier make the
adjustment.
4. After the adjustment has been made, press the
Panel Reset Key twice (or turn OFF the Power
Switch) to return the copier back into the normal
mode.
1139D019CA
D-56