Page 1
Caution Do not mark on the model and other components M82A with pen nor leave printed materials contacted “EYE” Examination Simulator on surface. Ink marks on the models cannot be removed. Instruction Manual Table of Contents ● Introduction Manufacturerʼs Note P. 1 ● Before You Start DOs and DONʼTs P.
Page 2
Introduction Manufacturer’s Note Manufacturer’s Note Please read the instruction carefully before use. Before Use ● “EYE” Examination simulator is designed to help you practice examination of the optic fundus with an ophthalmoscope. So please do not use this model for any purpose other than medical practice and study, and please read the instructions carefully. We are not responsible for any damage caused by use that is not accepted by this instruction.
Page 3
Before You Start DOs and DONʼTs Caution ・Please use direct ophthalmoscope with an anti reflection filter. ・On opening and closing the eyelid, please do as you would with an actual patient. ・The surface of the case images must be handled with the utmost care. Please take care that the images are not stained and damaged. On removing dust on the images, please use the blower included. ・When changing the diameter of the pupil, please turn the gear softly. Please do not turn the gear with excessive force. DOs and DONʼTs DOs DONʼTs Handle with Care ・Do not ever wipe the simulator with thinner or organic solvent. ・The materials for the models are a special composition of soft resin. Please handle ・Do not mark on the simulator models with with the utmost care. pen or leave any printed materials in contacted with the surface. Ink marks on the models will ・Store the simulator in the case at room not be removable. temperature. Keep away from heat, moisture, and direct sunlight. 2...
Page 4
Before You Start Set includes Set Includes Before your first use, ensure all components listed below are included in the unit. Specifications Manikin : Life size of an adult male head Material : soft resin, hard resin Weight : 2kg approx. Dimensions : Manikin W42×D22×H38cm Set includes A. Manikin head and shoulder B. set of case slides(10 cases) C. Manual D. Study guide E. Slide holder F. Blower G. Storage case Replacement Parts set of fundus images (10 cases, left and right for each) 11220-010 1...
Page 5
Before You Start Before You Start Preparation Preparation Preparation 1. Setting of the slides 1.Remove the head cover on the back of the head. 2.Pull out the slide holder from the eyeball unit. The slide holder is set with bearings on the inner wall of the eyeball unit. To pull it out, please grasp the center of the holder.
Page 6
Before You Start & After Training Preparation 4. As shown in the picture, incline the slide holder a little and insert it into the eyeball unit. 5. Set the head cover. First set the bottom part of it, then fit the upper part. 2.
Page 7
Caution materials contacted on their surface. Ink marks on the models will be irremovable. For inquiries and service, please contact your distributor or KYOTO KAGAKU CO., LTD. KyotoKagaku America Inc. USA,Canada,and South America The contents of the instruction manual are subject to change without prior notice.