ABB ACS 580-OP Manual page 41

With bypas
Hide thumbs Also See for ACS 580-OP:
Table of Contents

Advertisement

Supplemental Installation Manual for ACS580-0P
ACS580-0P, packaged drive with circuit breaker disconnect and two-contactor
bypass, UL (NEMA) Type 3R
Dimension
Reference
CX3R-21
CX3R-22
CX3R-23
CX3R-24
CX3R-25
H1 - Height
H2 - Mounting Height
W1 - Width
W2 - Mounting Width
W1
W2
WARNING
WARNING
!
Wait at least 5 minutes after disconnecting
RISK OF FIRE OR ELECTRIC SHOCK-
supply before continuing to work.
Consult the Installation & Start-Up Manual
The opening of the branch-circuit protective device may
before working on the frequency converter.
be and indication that a fault current has been
ATTENTION!
!
interrupted. All current-carrying parts and other
components protected by this device should be
Attendre au moins 5 min apres sectionnement
de l'alimntation pour travailler sur l'appareil.
examined and replaced if damaged. If burnout of a
Consulter le Manuel d'installation et de mise
current element of an overload relay occurs, the
end route avant d'intervenir sur le convertisseur
complete overload relay must be replaced.
de frequence.
CAUTION
VOLTAGE MAY BE PRESENT FROM MORE
THAN ONE SOURCE AND SHOULD BE
DISCONNECTED FOR SERVICING.
ATTENTION
PEUT ETRE SOUS TENSION DE PLUS D'UNE
SOURCE D'ALIMENT ELECTRIQUE. COUPER TOUTES LES
SOURCES D'ALIMENTATION AVANT LE DEPANNAGE.
OFF
DRIVE
BYPASS
Height (H1)
Height (H1)
in
mm
in
mm
27.34
694
22.50
572
33.00
838
28.50
724
39.40
1001
34.50
876
51.00
1295
46.50
1181
72.00
1829
58.60
1488
D
H1
H2
Width (W1)
Width (W2)
in
mm
in
mm
18.21
463
16.50
419
24.00
610
22.50
572
30.00
762
28.50
724
36.00
914
34.50
876
42.00
1067
34.50
876
W1
W2
WARNING
RISK OF FIRE OR ELECTRIC SHOCK-
The opening of the branch-circuit protective device may
be and indication that a fault current has been
CAUTION
components protected by this device should be
interrupted. All current-carrying parts and other
examined and replaced if damaged. If burnout of a
VOLTAGE MAY BE PRESENT FROM MORE
complete overload relay must be replaced.
current element of an overload relay occurs, the
THAN ONE SOURCE AND SHOULD BE
DISCONNECTED FOR SERVICING.
!
WARNING
ATTENTION
Wait at least 5 minutes after disconnecting
supply before continuing to work.
before working on the frequency converter.
Consult the Installation & Start-Up Manual
PEUT ETRE SOUS TENSION DE PLUS D'UNE
!
ATTENTION!
SOURCE D'ALIMENT ELECTRIQUE. COUPER TOUTES LES
de l'alimntation pour travailler sur l'appareil.
Attendre au moins 5 min apres sectionnement
SOURCES D'ALIMENTATION AVANT LE DEPANNAGE.
Consulter le Manuel d'installation et de mise
de frequence.
end route avant d'intervenir sur le convertisseur
OFF
DRIVE
BYPASS
41
Depth (D)
Weight
in
mm
lb
kg
14.38
365
90
41
14.37
365
145
66
15.87
403
230
105
20.37
517
445
202
25.10
638
675
307
D
H2
H1
ACS580-0P with Bypass