6.3 Safety instructions for maintenance

o Check the mains connection cable for damage from time to time. Never operate the
device when the cable is damaged. A damaged cable must immediately be replaced
by customer service or a qualified electrician to avoid dangers.
o When you encounter damages or failures contact your specialist dealer or our
customer service. Pay attention to the troubleshooting tips in pt. 7.
o Only qualified experts may perform repair and maintenance work on the device using
original replacement and accessory parts. Never attempt to repair the device
yourself!

7. Possible Malfunctions

Problem
Unit is connected to a
power source, green
control light does not
come on, unit does not
heat up.
The orange heating
control light comes on,
the temperature does not
increase.
Green control light
comes on but the orange
heating control light does
not come on in spite of
desired temperature
being reached.
Cause
Plug improperly inserted
into socket
Blown fuse
Switching unit is
improperly installed
Overheating protection
has turned off
No contact with
microswitch
Damaged temperature
control (overheating
security)
Interrupted contact with
the heating element
Damaged heating
element
Set temperature has
been reached
Damaged temperature
control
Damaged control light
Removal
Remove plug and insert
properly
Check fuses, connect
unit to another socket
Check the location of
the switching unit
Press RESET on the
switching unit
Contact sales agent
Contact sales agent
Contact sales agent
Contact sales agent
Check functioning at
different temperature
Contact sales agent
Contact sales agent