Check the intake air
a Lock screw
b Air sleeve
Gap X must measure:
– ½" (13 mm) for natural gas
– ½" (13 mm) for LP (propane) gas
^ To adjust the gap, loosen the lock
screw and slide the air sleeve in or
out as necessary.
^ Tighten the lock screw.
^ Use sealant to secure the jets and
prevent loosening.
^ Reassemble the cooktop in reverse
order.
The flame must not go out on the lowest
setting, or when the control is turned
quickly from a high to a low setting.
On the highest setting the flame must
have a distinctive and visible core.
Converting CS 1011
Changing the needle valves
a Needle valve with small jet
b Needle valve with large jet
^ Using a small screwdriver, unscrew
the needle valves and remove them
with a pair of needle nose pliers.
^ Insert the new valves and screw them
in place.
^ Use sealant to secure the jets and
prevent loosening.
,
Check all fittings for gas leaks
before reassembling the cooktop.