OPERATING MANUAL
Critical error
Supply error
A critical error cannot be eliminated via a RESET.
The light curtain must be switched on and off. If the error should persist, please contact Pilz
customer services.
Operating
mode of
Information
light
curtain
Light beams - reduced range
Normal
Light beams - long range
operating
Test
mode
Light beams
Microprocessor error
Lens error
Error
BCM configuration error
Communication error
Critical error
A critical error cannot be eliminated via a RESET.
The light curtain must be switched on and off. If the error should persist, please contact Pilz
customer services.
52
Transmitter side (TX):
LED DISPLAY
PSEN op2H-A series
Switch light curtain
on/off.
If the problem should
persist, please contact
Pilz customer services.
Check the power supply
connection.
If the problem should
persist, please contact
customer services.
Meaning of LED
Suggested action
Check the wiring of the TEST.
Activate RESET.
If the problem should persist,
please contact Pilz customer
services.
Activate RESET.
If the problem should persist,
please contact Pilz customer
services.
Perform basic configuration again.
If the problem should persist,
please contact Pilz customer
services.
Activate RESET.
Check the cascading connection
and check that the end cap is
installed correctly.
Switch light curtain on/off.
If the problem should persist,
please contact Pilz customer
services.