6.1 Reset to factory configuration

The user has the option to re-establish the light curtain's factory configuration by operating
the pushbuttons as described below:
1. Press the CONFIRM button and keep it held down for at least 9 s (but not more than
30 s, so that the light curtain is not blocked)
2. The LEDs flash briefly, indicating that the light curtain has been reset to the factory
configuration
3. After the reset has occurred, the light curtain resumes its normal operation with the
factory configuration.
NOTE: Restoring the factory settings will delete the BCM configuration.

6.2 Function list

NOTE: The table highlights the default configuration in bold.
Legend for LED display in RX/TX function list
LED off, LED is not relevant for the information in the "Function" column
LED off, LED is relevant for the information in the "Function" column
LED yellow, value in the "Setting" column is valid for the information in the
"Function" column
LED red, value in the "Setting" column is valid for the information in the "Function"
column
LED green, value in the "Setting" column is valid for the information in the
"Function" column
Function
Partial Muting
EDM
Restart mode
Muting direction
Muting timeout
Activation of
override
1003069-EN-03
List of RX functions in muting mode
(LED 3 lights up yellow)
LED
Setting
No.
2
See the following table
3
4
Activated
Deactivated
5
Auto
Manual
6
T (bidirectional)
L (one-directional)
7
10 min
Infinite
8
Level
Edge
PSEN op2H-A series
LED status
LEVEL
33