• Activated by edge: When the contacts are closed, the override remains activated until
at least one muting sensor has been interrupted. In this case, the override status is
also maintained if the override contacts are opened. The device switches the override
status if any of the following events occurs:
− The muting sensors are deactivated (T-Muting) or the muting sensors are
deactivated AND no beams are interrupted (L-Muting).
− The timeout time elapses.
OVERRIDE STATE: This is an output signal which provides the user with information
as to whether the override inputs are active and the override conditions are present.
Level
Edge
1003069-EN-03
Fig. 48 – Override timings (activated by edge)
BCM configuration: Override mode
LED 8 ON green
LED 8 OFF
PSEN op2H-A series
LEVEL
49