Pilz PSEN op2H-A Series Operating Manual page 26

Safety light curtain
Table of Contents

Advertisement

OPERATING MANUAL
12-pin
CONNECTION
RESET
RESTART
ALIGNMENT
OVERRIDE 1
OVERRIDE 2
EDM
MUTING
DEACTIVATION
OSSD1 / OSSD 2
OVERRIDE
STATUS
MUTING LAMP
MUTING1/MUTING2
FUNCTION EARTH
CONNECTION
TEST
REDUCED RANGE
FUNCTION EARTH
26
Assignment of M12 connector
PSENopt Advanced RX Muting
LINE
24Vdc
IN line
N.O.
24Vdc
IN line
N.O.
24Vdc
IN line
N.O.
24Vdc
IN line
N.O.
IN line
N.O.
See section 7.4 for
connections
24Vdc
IN line
N.O.
OSSDs
0V
OSSDs
0V
24Vdc
LAMP
24Vdc
IN line
N.O.
PSENopt Advanced TX
LINE
24Vdc
IN line
N.O.
24Vdc
IN line
N.O.
BEHAVIOUR
Is connected – when in disabled state the
RESET/RESTART/ALIGN button is operated
Is connected – when during operation the
RESET/RESTART/ALIGN button is operated
Has to be set to 24 V DC at startup
Is connected – when Override is active during
operation
No voltage – during operation
Must be non-equivalent to OSSD during operation
with EDM enabled
Muting is disabled when connecting
Protected field clear
No voltage = Protected field not clear
High level = Override function active
Low level = Override function inactive
NOTE: This line signals the state of the override
signal inputs
The open collector connection is activated when
muting is activated.
Is connected – when muting is active during
operation
Connect to earth
BEHAVIOUR
Is connected – when the RESET button is
operated during operation
Has to be set to 24 V DC at startup
Connect to earth