4.1 Connection guidelines

The following section contains some guidelines regarding the connections, which should be
followed to ensure the correct operation of the safety light curtain from the PSEN op2H-
A series.
• Never place connection cable close to or in contact with cables featuring high voltage
ratings and/or current fluctuations (e.g.: motor supply, inverters etc.).
• Never combine the OSSD wires from several safety light curtains into one multi-pole
cable.
• The TEST wire must be connected to the light curtain's operating voltage via a
pushbutton with N/O contact.
• Use the light curtain with protection class III with SEL/PELV external supplies for power
supply.
The RESET button must be positioned so that the user can check
the protected field during any test.
The RESET/RESTART/ALIGN button must be positioned so that the
user can check the protected field during all reset operations.
• The light curtain is already equipped with internal suppressors for overvoltage and
overcurrent. We would advise against using additional components.
Example: Connection to the safety relay
Automatic start
1003069-EN-03
Fig. 20 – Connection to safety relay – automatic start