In the following cases, the chlorinator shuts down and the alarm and
acoustic alarm LED is activated (automatic reset once the fault is solved):
"NO
WATER
FLOW"
"SHORT CIRCUIT"
"OPEN CIRCUIT"
"Chlorine Alarm"
Manual PRO v.3
Excess
gas
in
electrolysis cell. It may
have occurred because the
pump has shutdown. The
gas is hydrogen gas which
is highly flammable.
Sensor cable of the cell is
incorrectly connected or
broken.
Cell sensor is dirty.
No water flow
The
cell
is
incorrectly
connected.
Metal body in the cell.
Cell
is
incorrectly
connected.
Cell
is
damaged
completely worn down.
Swimming pool water with
very
low
concentration.
Chlorine
probe
incorrectly connected or
damaged
Water contains very low
redox potential.
The equipment does not
have a probe and is in
"automatic mode".
the
The piping should be drained to
eliminate gas or accumulated
water. Check the pump.
Check the sensor cable (white
cable)
Clean.
See maintenance.
Check the water system
Check wiring.
Turn off the equipment and
remove the metal body from the
plates
Check the cell connection and
ensure
that
connection terminals are in good
condition.
or
Check the condition of the cell
electrodes, and replace it if any
damage is observed.
Ensure that the water has salt
salt
and that it is dissolved.
is
Check the cabling of the probe
and the probe itself. Check 5.1.
It can work in manual mode if
necessary.
Leave the equipment to chlorate
in manual mode for at least 2
hours.
Check the chemical balance of
the water. (appendix 1)
Install a Redox or Free Chlorine
probe,
or configure
mode.
cables
and
"manual"
73 / 78