Hide thumbs Also See for BSPOOL PRO200:

Advertisement

Quick Links

CLORADOR SALINO
SALT WATER CHLORINATOR
ÉLECTROLYSEUR AU SEL
PRO200 / PRO250 / PRO500 /
PRO750 / PRO1000
MANUAL DE USUARIO
USER MANUAL
MANUEL DE L'UTILISATEUR
1 / 53
Manual PRO v.2

Advertisement

Table of Contents
loading

Summary of Contents for BSV BSPOOL PRO200

  • Page 1 CLORADOR SALINO SALT WATER CHLORINATOR ÉLECTROLYSEUR AU SEL PRO200 / PRO250 / PRO500 / PRO750 / PRO1000 MANUAL DE USUARIO USER MANUAL MANUEL DE L'UTILISATEUR 1 / 53 Manual PRO v.2...
  • Page 2 PLEASE NOTE IN THE FOLLOWING CARD THE REGISTRATION DATA OF THE EQUIPMENT YOU HAVE PURCHASED, WHICH ARE FOUND ON THE SIDE LABEL. THESE DATA WILL BE OF USE IF YOU WISH TO MAKE ANY ENQUIRY TO YOUR SUPPLIER OR TO BSV ELECTRONIC S.L. MODEL……………………………………………… REF. ………………………………………………….. VOLTAGE……………………………………………..
  • Page 3: Table Of Contents

    INDEX 1-GENERAL DESCRIPTION 1.1- BSV PRO units …………………….. …………….……………………………………………………………………… 1.2- Technical specifications……………..…………………………………………………………………………………… 32 1.3- Recommendations and safety precautions…….………………………………………………………………… 32 2- PREPARING THE SWIMMING POOL 2.1- Adding salt to the water ………………………………………………………………………………………………… 33 2.3- Chemical balance of the water..……………………………………………………………………………………… 3- INSTALLATION 3.1-...
  • Page 4: 1-General Description

    Before installing the salt water chlorinator, please read this manual carefully. If you need to clarify any point or have any doubts, please contact your dealer or BSV ELECTRONIC S.L. directly. We will be delighted to assist you. 1-GENERAL DESCRIPTION 1.2 BSV PRO salt water chlorination equipment...
  • Page 5: Technical Specifications

    1.2- Technical specifications 1.2.1- Equipment PRO200 Models PRO250 PRO500 PRO750 PRO1000 Supply 230Vac 230Vac 230Vac 230Vac 230Vac voltage 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz Chlorine production 1000 g/hour Max. power 1350W 1750W 3500W 5250W 7000W Cell current Dimensions Weight 15Kg 20Kg 30Kg 40Kg 50Kg...
  • Page 6: 2- Preparing The Swimming Pool

    Ensure that the heatsink wings are not blocked and that air can easily circulate through them. BSV PRO equipment incorporate protection systems against short circuits in the cell, absence of water detector and other safety systems that give an acoustic and visual alarm in the event of any anomaly. However, for optimum results, you should ensure the correct hydraulic operation of your swimming pool.
  • Page 7: Chemical Balance Of The Water

    We recommend using salt that is especially prepared for use in salt water chlorination installations, as it is especially prepared for rapid dissolution and to achieve optimum results. You can find it at retailers specializing in swimming pool products. ATTENTION When adding salt to the swimming pool, first disconnect the chlorinator (position OFF), and start-up the filter for 3 or 4 hours, in order for the salt to dissolve and not to overload the equipment.
  • Page 8: General Considerations

    COPPER (mg/l) <1.5 ALKALINITY (mg/l) CONDUCTIVITY (us/cm) <1700 TDS (mg/l) <1000 HARDNESS (mg/l) 3-INSTALLATION OF THE EQUIPMENT 3.1- General considerations::  Place the chlorination cell in the highest position possible of the purification circuit and always after the filter.  If possible, it is recommended to install the cell with a by-pass system with its corresponding shut-off valves.
  • Page 9: Hydraulic Connection Diagram

    3.2- Hydraulic connection diagram 3.2.1- Diagram Electrolisys cell Recommended installation (PRO250) 1. FILTRATION 2. CONTROL PANEL 3. FLOW SWITCH 4. ELECTROLYSIS CELL 5. PRO250 UNIT(*) 36 / 53 Manual PRO v.2...
  • Page 10: 7- Amperometric Probe Kit

    Recommended installation (PRO750) 1. FILTRATION 2. CONTROL PANEL 3. FLOW SWITCH 4. ELECTROLYSIS CELL 5. PRO750 UNIT(*)  (*) The PRO250, PRO500, PRO750 and PRO1000 units follows the same hydraulic scheme, connecting in parallel as many cells as power modules. ...
  • Page 11 the pH value at the middle point, within the range from pH 7.0 to 7.4. Outside these ranges of pH, side reactions occur on the surface of the electrode which prevent the readings generated from being corrected. 3.2.2.1- Indications STATUS INDICATOR LED Fixed blue Led: normal operation Quick flashing blue Led (2Hz): automatic cleaning Slow flashing blue Led (1Hz): Stabilization time after cleaning.
  • Page 12: Electrical Connection Diagram

    3.3- ELECTRICAL CONNECTION DIAGRAM 3.3.1- PRO250/500/750/1000 units All the PRO series units can be configured to work with single or three- phase supply, depending on the installation needs. instalación. Single-phase connection Ensure the line supply has all the protections and the correct cable size according with the current consumption (see table on page 32) Remove the upper cover of the unit to be able to see the terminal strips.
  • Page 13 Connection to the three-phase line: Ensure the line supply has all the protections and the correct cable size according with the current consumption (see table on page 32) Remove the upper cover of the unit to be able to see the terminal strips. Connect the cables to the three-phase line (380V).
  • Page 14 Option A) Line supply by means of the filtration pump contactor: o Connect the chlorinator’s input line directly to the filtration pump contactor o Ensure that the contactor is correctly sized to be able to hold the pump + chlorinator current (see page 32). o Use separate contacts to supply the pump and the chlorinator.
  • Page 15 Cell cable connection All the PRO series chlorinators are supplied with the cables already connected to its power supplies. Once the cells are installed, connect every power supply to its cell, using the included hardware to attach it on every side of the cell. Ensure all the cables are tightly connected with the cell.
  • Page 16: 4- Operation

    4- OPERATION 4.1 PRO250, PRO500, PRO750, PRO1000 units The SMART series equipment has an LCD screen, in which you can view and configure all operations of the equipment. The following table shows how to organize the configuration menu of the equipment: Chlorinator Menu Chlorinator menu Main menu...
  • Page 17: 1- Main Screen

    4.1.1- Main screen On starting up the equipment, a screen will be displayed with the main parameters. En la línea superior se muestra el % de producción de cada una de las fuentes que incorpore el equipo En la segunda línea se muestra la tensión de cada fuente La tercera línea muestra la lectura de la sonda de cloro libre, en caso de estar instalada.
  • Page 18 Using the buttons   you can select a line of the menu, indicated by the arrow (). The OK button is used to confirm the selection. To access the configuration menu, you need to confirm the operation by selecting (S) through the arrow, and pressing OK. 4.1.3- Language From the configuration menu select "Language", press the OK button, and once the required language has been selected, press the OK button and EXIT.
  • Page 19 It is possible to select cleaning intervals from 1 to 8 hours. 4.1.6- Chorine menu With this menu you can select all parameters related to chlorine production. 4.1.6.1- Chlorine production Configuration of the maximum production of chlorine. From 0% to 100% Press “OK” and use the arrows   to change the value. Press "OK"...
  • Page 20: Warning Messages And Alarms

    Once the reading has stabilized and the chlorine measurement has been taken with DPD1, adjust the PPM value provided by the DPD1 measurement. 4.2- Warning message and alarms In the event of abnormal operation, the SMART series equipment will display an alarm message on the 4th line of the screen, together with an acoustic warning.
  • Page 21 radiator fins Place the equipment so that air obstructed or are not in a is circulated for correct cooling. vertical position. 4.2.2- Alarm Messages In the following cases, the chlorinator shuts down and the alarm and acoustic alarm LED is activated (automatic reset once the fault is solved): "NO WATER Excess...
  • Page 22: 5- Maintenance

    The equipment does not Install a Redox or Free Chlorine have a probe and is in probe, or configure "manual" "automatic mode". mode. 4.3- Working hours It may be useful to see the operation times for regular maintenance operations. From the main screen, press both buttons   at the same time. 5- MAINTENANCE 5.1- Checking and maintenance of the Amperometric probe (free chlorine)
  • Page 23 the water without free 1 hour. chlorine Adjust the flow reaching the sensor Reading below the Insufficient flow in the sensor holders. Clean the filter and the flow DPD-1 measurement holders regulator of the sensor holders. Bleed the sensor holders and ensure There are air bubbles in the that there is no air remaining in the measuring zone of the sensor...
  • Page 24 Failure in sealing of the sensor Check sealing rings of the sensor The pH of the water is lower Calibrate the sensor at the new pH than at the time of calibration value The pH is lower than 6.5 and therefore outside the Adjust the pH to within the acceptable recommended reading zone...
  • Page 25: 6-Warranty And Service

    6-WARRANTY AND SERVICE BSV Electronic S.L. guarantees its BSPOOL equipment for a period of 2 years in control centres. The electrolysis cells have a control of two years, as long as they have not exceeded 10,000 hours of use. This guarantee is given to the owner of the equipment and it is not transferable.
  • Page 26: Annex 1: Electrical Connection Schematic

    Annex 1: Electrical connection schematic 53 / 53 Manual PRO v.2...

This manual is also suitable for:

Bspool pro250Bspool pro500Bspool pro750Bspool pro1000

Table of Contents