Rinstrum 400 Series Operator's Manual

Rinstrum 400 Series Operator's Manual

Batching indicator
Hide thumbs Also See for 400 Series:

Advertisement

Quick Links

400 Series
(K410)
Batching Indicator
Operator Manual
004R-614-120

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 400 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Rinstrum 400 Series

  • Page 1 400 Series (K410) Batching Indicator Operator Manual 004R-614-120...
  • Page 2 Rinstrum Pty Ltd. Disclaimer Rinstrum Pty Ltd reserves the right to make changes to the products contained in this manual in order to improve design, performance or reliability. The information in this manual is believed to be accurate in all respects at the time of publication, but is subject to change without notice.
  • Page 3: Table Of Contents

    Operator Manual - Software Version 1.x & 2.x Table of Contents 1. INTRODUCTION................3 2. SAFETY ..................4 2.1. Operating Environment ............4 2.2. Electrical Safety ..............4 2.3. Cleaning..................4 3. BASIC OPERATION..............5 3.1. User Interface Display and Controls ........5 3.2. Display ..................6 3.3. Annunciators ................7 3.4.
  • Page 4 Operator Manual - Software Version 1.x & 2.x 4.16. Rename Product (v2.x software Only)........19 5. FUNCTION KEYS ..............20 Overview ..................20 Print, Report Key ................20 Single Key ..................20 Blanking Input ................20 Start....................20 Pause, Abort, PSE.ABT, SUSPND ..........20 Test ....................21 6. ERROR MESSAGES ..............22 6.1.
  • Page 5: Introduction

    Operator Manual - Software Version 1.x & 2.x 1. Introduction This instrument is a precision digital indicator designed for gain in weight batching applications. It supports up to 32 input/outputs. It may be operated from either a DC power source (12V ) or AC power (optional 110 –...
  • Page 6: Safety

    Operator Manual - Software Version 1.x & 2.x 2. Safety 2.1. Operating Environment • Operating Temperature: –10 to 50°C • Humidity: <90% non-condensing • Operating Voltage: Shown on Rear Label 2.2. Electrical Safety • For your protection all mains electrical hardware must be rated to the environmental conditions of use.
  • Page 7: Basic Operation

    Operator Manual - Software Version 1.x & 2.x 3. Basic Operation 3.1. User Interface Display and Controls Code Description Display Opto-link connection point Power Key Function Keys (Fixed) Function Keys (user defined) Numeric Keypad 004R-614-120 Page 5...
  • Page 8: Display

    Operator Manual - Software Version 1.x & 2.x 3.2. Display Code Description Primary Annunciators Primary Display Auxiliary Display Primary Units Secondary ID Miscellaneous Annunciators Secondary Units Secondary Display Page 6 004R-614-120...
  • Page 9: Annunciators

    Operator Manual - Software Version 1.x & 2.x 3.3. Annunciators Primary Annunciators Visible when the displayed reading is HOLD held. Visible when the displayed reading represents Net weight. Visible when the gross reading is within ZERO ± ¼ of a division of true zero. Visible when the displayed reading is MOTION not stable.
  • Page 10: Keypad

    Operator Manual - Software Version 1.x & 2.x 3.4. Keypad Code Description Numeric Button White Additional Functions (Hold 2 seconds) Characters Orange (Alpha and Symbols) Characters Cancel Undo last command; step backwards (including in menus). Move cursor backwards; previous option Down Move cursor forwards;...
  • Page 11: Basic Operation

    Operator Manual - Software Version 1.x & 2.x 3.5. Basic Operation Power Key ON Instrument OFF Instrument Zero Key 004R-614-120 Page 9...
  • Page 12: Tare Key

    Operator Manual - Software Version 1.x & 2.x Tare Key Recipe Key <RECIPE> is used to enter product recipe details. The recipe details of target for each fill, number of batches, proportion and preset tare are shown for operator entry, if they have been enabled in the batching setup.
  • Page 13: Stability Considerations

    Operator Manual - Software Version 1.x & 2.x 3.6. Stability Considerations Some functions (E.g. Tare and Zero) require a stable weight. These functions will wait for up to 10 seconds for stable weight. 3.7. Security All keyboard functions can be locked in setup. The locking options are: •...
  • Page 14: Additional Functions

    Operator Manual - Software Version 1.x & 2.x 4. Additional Functions 4.1. System Time and Date (Clock - 1 key) 4.2. Display View (View – 2 key) View (Product, Top) Page 12 004R-614-120...
  • Page 15: Reports (Report - 3 Key)

    Operator Manual - Software Version 1.x & 2.x 4.3. Reports (Report - 3 key) 4.4. Totals (Total - 4 key) 004R-614-120 Page 13...
  • Page 16: Id Names (Id - 5 Key)

    Operator Manual - Software Version 1.x & 2.x 4.5. ID Names (ID – 5 key) 4.6. Pulse Timers (Timers – 6 key) Stage 1 Stage 2 ..Stage 10 Timers Name of pulse stage Page 14 004R-614-120...
  • Page 17: Set Point Targets (Target - Key 7)

    Operator Manual - Software Version 1.x & 2.x 4.7. Set Point Targets (Target – key 7) Target (Setpoint Targets) 4.8. Flight Settings (Flight – key 8) Flight (FLIGHT, M.PRE, F.PRE Mat 1 for each material) Mat 2 Mat 6 004R-614-120 Page 15...
  • Page 18: Tolerance (Tol - Key 9)

    Operator Manual - Software Version 1.x & 2.x 4.9. Tolerance (Tol – key 9) Stage 1 Stage 2 Stage 10 (TOL.LO, TOL.HI Mat 1 for each FILL stage) Mat 2 Mat 6 4.10. Lock Page 16 004R-614-120...
  • Page 19: Alibi

    Operator Manual - Software Version 1.x & 2.x 4.11. Alibi Switching to Alibi Mode Returning from Alibi Mode 4.12. Accessory Modules (Acc – 0 key) 004R-614-120 Page 17...
  • Page 20: Product Selection (V2.X Software Only)

    Operator Manual - Software Version 1.x & 2.x 4.13. Product Selection (v2.x software Only) 4.14. Add Product (v2.x software Only) Page 18 004R-614-120...
  • Page 21: Delete Product (V2.X Software Only)

    Operator Manual - Software Version 1.x & 2.x 4.15. Delete Product (v2.x software Only) 4.16. Rename Product (v2.x software Only) 004R-614-120 Page 19...
  • Page 22: Function Keys

    Operator Manual - Software Version 1.x & 2.x 5. Function Keys Overview The instrument supports up to eight (8) special functions. They can be configured for: print, single, test, blank, start, pause, abort, pse.abt and report. Print, Report Key A Print key will initiate a RECORD printout. A report key will initiate a REPORT printout.
  • Page 23: Test

    Operator Manual - Software Version 1.x & 2.x A pause/abort (PSE.ABT) key combines the two functions using a short and long press of the key: short key press to pause and a long key press to abort the batch. To resume batching from pause press the START key.
  • Page 24: Error Messages

    Operator Manual - Software Version 1.x & 2.x 6. Error Messages 6.1. Weighing Errors These messages show status messages or errors that may occur during normal weighing operation. Error Description Resolution U.LOAD The weight is below the Increase the weight or minimum allowable weight decrease the reading.
  • Page 25: Pause Conditions

    Operator Manual - Software Version 1.x & 2.x 6.2. Pause Conditions The following table lists the possible pause messages that may be displayed due to the condition noted. Error Description Resolution "OPER" Operator pause via Press Start when ready function key to restart batching.
  • Page 26 Operator Manual - Software Version 1.x & 2.x Notes: Page 24 004R-614-120...
  • Page 27 Notes...

This manual is also suitable for: