Page 1
400 Series (K410) Batching Indicator Operator Manual 004R-614-120...
Page 2
Rinstrum Pty Ltd. Disclaimer Rinstrum Pty Ltd reserves the right to make changes to the products contained in this manual in order to improve design, performance or reliability. The information in this manual is believed to be accurate in all respects at the time of publication, but is subject to change without notice.
Operator Manual - Software Version 1.x & 2.x 1. Introduction This instrument is a precision digital indicator designed for gain in weight batching applications. It supports up to 32 input/outputs. It may be operated from either a DC power source (12V ) or AC power (optional 110 –...
Operator Manual - Software Version 1.x & 2.x 2. Safety 2.1. Operating Environment • Operating Temperature: –10 to 50°C • Humidity: <90% non-condensing • Operating Voltage: Shown on Rear Label 2.2. Electrical Safety • For your protection all mains electrical hardware must be rated to the environmental conditions of use.
Operator Manual - Software Version 1.x & 2.x 3.3. Annunciators Primary Annunciators Visible when the displayed reading is HOLD held. Visible when the displayed reading represents Net weight. Visible when the gross reading is within ZERO ± ¼ of a division of true zero. Visible when the displayed reading is MOTION not stable.
Operator Manual - Software Version 1.x & 2.x Tare Key Recipe Key <RECIPE> is used to enter product recipe details. The recipe details of target for each fill, number of batches, proportion and preset tare are shown for operator entry, if they have been enabled in the batching setup.
Operator Manual - Software Version 1.x & 2.x 3.6. Stability Considerations Some functions (E.g. Tare and Zero) require a stable weight. These functions will wait for up to 10 seconds for stable weight. 3.7. Security All keyboard functions can be locked in setup. The locking options are: •...
Operator Manual - Software Version 1.x & 2.x 5. Function Keys Overview The instrument supports up to eight (8) special functions. They can be configured for: print, single, test, blank, start, pause, abort, pse.abt and report. Print, Report Key A Print key will initiate a RECORD printout. A report key will initiate a REPORT printout.
Operator Manual - Software Version 1.x & 2.x A pause/abort (PSE.ABT) key combines the two functions using a short and long press of the key: short key press to pause and a long key press to abort the batch. To resume batching from pause press the START key.
Operator Manual - Software Version 1.x & 2.x 6. Error Messages 6.1. Weighing Errors These messages show status messages or errors that may occur during normal weighing operation. Error Description Resolution U.LOAD The weight is below the Increase the weight or minimum allowable weight decrease the reading.
Operator Manual - Software Version 1.x & 2.x 6.2. Pause Conditions The following table lists the possible pause messages that may be displayed due to the condition noted. Error Description Resolution "OPER" Operator pause via Press Start when ready function key to restart batching.