6.2

Conditions for usage and installation

Necessary on-site preparatory work at the customer's premises are to be arranged
by the machine operator. The work must be carried out by authorised installation
technicians in compliance with general, country-specific and local regulations. The
WMF service engineers may only connect the machine to existing prepared connection
points. WMF Service is neither authorised nor responsible for carrying out any on-site
installation work prior to connection.
The potential equalization terminal is installed by WMF Service if needed.
Mains voltage tolerance range 220–240 V +6 % and–10 %,
Ambient temperature
Maximum humidity
Degree of protection
Installation Surface / 
water spray
Installation clearances
Ventilation
These specifications for the electrical connection and the standards quoted apply for connecting the
device in EU countries. It may be necessary to also observe additional country-specific regulations.
Outside the EU countries acceptance of the standards quoted is to be checked by the legal entity or
natural person who wishes to use the machine.
The local power supply must be constructed according to IEC 364. To improve safety, the device should be fitted with
an FI 30 mA earth leakage current circuit breaker complying with EN 61008. Near the device or about 30 cm below the
counter top there should be a shockproof socket as a single-phase connection installed locally on the rear or side wall
of the counter substructure or a country-specific single-phase socket. The socket is part of the on-site installation. The
mains cable must not come into contact with hot surfaces. If the mains cable for this device is damaged then it must
be replaced by our service personnel or a similarly qualified person, in order to prevent hazards.
User Manual WMF Cup / WMF Cup&Cool
Mains voltage interruption < 50 ms: no interruption
of function
+5 °C to max. of 32 °C
80 % relative humidity without condensation.
Do not use device outdoors.
IP X0
The device must be placed and leveled on a horizontal,
sturdy, water-resistant, and heatproof base.
The device must not be cleaned using a water jet. The device
must be installed where it is protected against water spray.
The device must not located on a surface that is sprayed
or cleaned with a water hose, steam jets, steam cleaner, or
similar devices.
For operating, service and safety reasons the machine should
be installed with a clearance of not less than 50 mm at the
back and sides from the building or non-WMF components.
A clear height of 1,100 mm from the top of the supporting
surface should be ensured. The height of the installation
surface above the floor is at least 850 mm. If the machine
connections are to be run downwards through the counter,
please make space for the lines, which can reduce the usable
space below the machine.
Ensure adequate ventilation and cooling. A forced-air
ventilation may need to be provided on-site in order to
ensure sufficient heat dissipation.