Test Mode For Optional Unit (Job Separator) - Riso MZ870 Technical Manual

Table of Contents

Advertisement

10. Test Mode for Optional Unit (Job Separator)

No.
Sensor/switch
3100
Job separator tape jam sensor
3101
Job separator tape detection sensor
3102
Job separator power switch
3103
Job separator connection signal
No.
Tape output
3140
Outputs one tape.
* Test Mode No. 3170 Stamping Quantity is enabled
No.
Stamping quantity
Sets the number of stamping operations during Test Mode No. 3140 (Tape
Description
Output).
3170
Setting range:
Setting
Default: 0 (No stamping)
Tape jammed message <activate or deactivate>
Description
Displays/Hides the tape jam error display in tape output.
3171
Setting range:
Setting
Default: 1 (Enable)
Detecting condition
ON when tape is jammed.
ON where tape is detected.
ON when powered ON
Job separator is connected.
Unit check
Data setting
0 (No stamping)
1 (1 stamping)
2 (2 stamping)
* Returns back to the default setting when powered OFF.
0 (Disable)
1 (Enable)
[ 15-49 ]
MZ870 / MZ890 / MZ1070 / MZ1090 (Revision 0.9)
TEST MODE
Print drum
changeover
Print drum
changeover
Print drum
changeover