Riso MZ870 Technical Manual page 118

Table of Contents

Advertisement

PANEL MESSAGE
Error type
B31 [Network cable not connected]
B31-***
Panel display
!! No Linked Printer Detected !!
Check Cable Connection and Power Supply for Linked Printer
Error reset
Press the Reset key.
method
Error point
916
The network cable was not connected when the machine starts up.
Error detected by NET-D (NAK received).
920
* No response from communication destination, interruption by communication destination, TCP/IP not
operating in the NET-D, or unauthorized interrupt received from the main unit, etc.
Error type
B32 [NIC: External communication error]
B32-***
Panel display
!! No Linked Printer Detected !!
Check Cable Connection and Power Supply for Linked Printer
Error reset
Press the Reset key. << Remove the cause of the error in the printer to cancel the error. >>
method
Error point
MIB information request error.
* Transmission not possible after waiting 3 seconds (WAK), no response from communication destination,
914
interruption by communication destination, TCP/IP not operating in the NET-D, or unauthorized interrupt
received from the main unit, etc.
No MIB information returned.
915
* No response from the NET-D (communication destination) for 50 seconds (error detected in main unit).
917
Network communication error.
Error type
B33 [IP address setup error]
B33-***
Panel display
No IP Address Assigned to This Printer
Contact Your Network Administrator
Error reset
Press the Reset key.
method
Error point
931
The DHCP is ON, but the DHCP server cannot be found.
MZ870 / MZ890 / MZ1070 / MZ1090 (Revision 0.9)
Error detecting condition
Error detecting condition
Error detecting condition
[ 16-84 ]