3 Pole terminal block
Match the corresponding active,neutral and the
ground wire and firmly tighten up the screws to
make sure the power line is not loose or
improperly connected, otherwise a short circuit
or fire could be caused.
Install plenum mounting bracket
● Overlap M8 bolt with washer and fixing metal
plates,and get bolts through the 4 holes on corners of
the plenum mounting bracket.
● Make sure fixing metal plates is 10mm distance from
the plenum mounting bracket in order to adjust angle
during installation.
● Push the plenum mounting bracket upward to snap into
the square hole.
Note
● Tighten M8 bolt to make sure the plenum mounting
bracket is connected with outdoor unit tightly.
● It's suggested that when screwing the bolt, torque
should be 7N.M which could make the connection
between outdoor unit and outlet gasket perfect.
● Check if the plenum mounting bracket is completely
embedded into the square hole.
Connect outlet air duct
● Snap the outlet air duct into the square hole on the
plenum mounting bracket ,Four fixed hole position
is naturally aligned.
● Screw the outlet air duct with the plenum mounting
bracket with 4 flat head screws from underneath the
plenum mounting bracket,support the square duct ring
by hand when screwing.
Square duct ring
Truss head screw
8
Fixed hole

Hide quick links: