Tecfluid 60 M-1 Series Instruction Manual

Variable area flowmeter

Advertisement

Quick Links

Technical Data
Accuracy:
± 2,5% of full scale value. Based on
VDE/VDI 3513
Scales:
In l/h, l/min, m³/h, kg/h, %, mm., etc
Scale length: 100 mm ± 5
Mounting:
Vertical (rising flow direction)
Total length: 220 mm ± 2
Pipe fittings: 1/4" BSP or NPT female thread
Working pressure:
Fluid temperature:
The glass can support a thermal shock of 150 ºC if there is
no internal pressure.
The temperature difference between the interior and exterior
of the glass tube must not exceed 80 ºC
Conforms with the Pressure Equipment Directive 97/23/EC.
This equipment is considered as being a pressure
!
accessory and NOT a safety accessory as defined in the
97/23/EC directive, Article 1, paragraph 2.1.3.
The following instruction manuals are attached:
60-AMD Limit Switch Instructions Manual
60-AMO Limit Switch Instructions Manual
60-AMH Limit Switch Instructions Manual
instrumentation
for fluids
Instructions Manual
10 ... 15 bar
-10 ... +100ºC
C-MI-60M1 Rev.: 0 English Version
Variable area
flowmeter
Series
60 M-1

Advertisement

loading

Summary of Contents for Tecfluid 60 M-1 Series

  • Page 1 Variable area flowmeter Series instrumentation 60 M-1 for fluids Instructions Manual Technical Data Accuracy: ± 2,5% of full scale value. Based on VDE/VDI 3513 Scales: In l/h, l/min, m³/h, kg/h, %, mm., etc Scale length: 100 mm ± 5 Mounting: Vertical (rising flow direction) Total length: 220 mm ±...
  • Page 2 Working Principle The flowmeter consists of a float inside a conical tube. The rising flow pushes the float to an equilibrium point. The area obtained between the float and the orifice is proportional to the flow rate. This type of measuring principle is known as variable Reading area.
  • Page 3 RECEPTION The flowmeter is supplied ready for installation and service. The blocking elements that hold the float for transport should be removed before installation. Turning the instrument up side down, check that the float moves freely in the tube. INSTALLATION The instrument must be installed taking into account the following: The fluid inlet will be in the bottom of the flowmeter (the one nearest the scale’s minimum value).
  • Page 4 WARRANTY TECFLUID guarantees all the products for a period of 24 months from their sale, against all faulty materials, manufacturing or performance. This warranty does not cover failures which might be imputed to misuse, use in an application different to that specified in the order, the result of service or modification carried out by personnel not authorized by Tecfluid, wrong handling or accident.