RIB PRINCE Installation Manual page 18

Reversible operator for leaf gates
Hide thumbs Also See for PRINCE:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 17
G
B
INSTALLATION PRINCE 230V REV.
P
RE-INSTALLATION CHECKS
The leaf must be fixed firmily on the hinges to the pillars, must not be flexible
during the movement and must move without frictions.
Before the installation of PRINCE, verify all dimensions etc.
There's no need for any modification, if the gate is like that shown in Fig. 1.
N.B.: Gate features must be uniformed with the standards and laws in force.
The door/gate can be automated only if it is in a good condition and its
conditions comply with the EN 12604 norm.
- The door/gate leaf does not have to have a pedestrian opening. In the
opposite case it is necessary to take the appropriate steps, in accordance
with EN 12453 norm (for instance; by preventing the operation of the motor
when the pedestrian opening is opened, by installing a safety microswitch
connected with the control panel).
M
ANUAL DRIVE OF THE LEAVES IN EMERGENCY
To move the gate it is sufficient to push the leaves manually.
In order to carry out the manual operation of the gate leaf the followings
must be checked:
- That the gate is endowed with appropriate handles;
- That these appropriate handles are placed so to avoid safety risks for the
operator;
- That the physical effort necessary to move the gate leaf should not be
higher than 225 N, for doors/gates for private dwellings, and, 390N for
doors/gates for commercial and industrial sites (values indicated in 5.3.5
of the EN 12453 norm).
F
IXING THE ACTUATOR ATTACHMENT TO THE COLUMN
To obtain a correct movement of the leaf gate it is necessary to respect the
measures.
In case an iron pillar is available, weld the bracket straight to it.
In case you need to fix the bracket onto a concrete pillar, use the fixing plate
as shown in picture 4, to be fastened with 4 Fischer screws of Ø 8 mm.
In the case you have a wall parallel with the open gate, you must provide a
niche in which to place the operator.
F
IXING THE ACTUATOR ATTACHMENT TO THE GATE
Then weld the second bracket to the gate (pictures 5, 6).
Make sure to stick to the measures mentioned in the table below during
installation
Fix PRINCE and try several times to open and to close the gate, controlling
that the screwcover does not touch the moving gate.
Parts to install meeting the EN 12453 standard
COMMAND TYPE
(out of public area*)
with manned operation
with visible impulses
(e.g. sensor)
with not visible impulses
(e.g. remote controldevice)
automatic
* a typical example are those shutters which do not have access to any public way.
A: C ommand button with manned operation (that is, operating as long as activated),
like code ACG2020.
B: Key selector with manned operation, like code ACG1010.
C: S afety edges and/or other safety devices to keep thrust force within the limits of
EN12453 regulation - Appendix A.
D: Photocells, like code ACG8026.
18
18
USE OF THE SHUTTER
Skilled persons
Skilled persons
(public area)
A
B
C
C
C
C and D
C and D
C and D
Unrestricted use
C and D
C and D
C and D
3
4
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

1 503 019Aa14045

Table of Contents