Z
Y
S1
X
S2
S3
Respect the measures for a correct installation
L
A
a
Min.÷Max
max
0
20
40
60
80
90°
100
1÷2
120
140
150
20
110°
Respect the measures WITH 2 MECHANICAL STOPPERS
L
A
a
Min.÷Max
max
0
20
40
60
90°
80
1÷2
100
110
20
110°
COL
Column attachment
B
C
D
E
100
100
765
90
100
100
765
90
100
100
765
90
110
100
765
90
140
110
765
115
160
110
765
115
180
110
765
115
210
110
765
115
220
120
765
115
110
140
765
90
B
C
D
E
100
100
730
90
100
100
730
90
100
100
730
90
110
100
730
90
140
110
730
115
160
110
730
115
180
120
730
115
100
140
730
90
T
COL
ANT
sec
13,5
S2-X
A
13,5
S2-Y
A
13,5
S3-X
A
14
S3-Y
A
17
S3-X
B
18
S3-X
B
19,5
S3-X
B
S1-Z
B
21,5
23
S1-Z
B
If the pillar is too large, and it is not possible to adjust
the actuator respecting the measure (B), you must
S1-Y
A
17
make a niche in the pillar or you have to move the gate
to the edge of the pillar.
T
COL
ANT
sec
13,5
S2-X
A
13,5
S2-Y
A
13,5
S3-X
A
S3-Z
A
14
17
S3-X
B
18
S3-X
B
20
S1-Z
B
16
S2-Y
A
19
19
ANT
Leaf attachment
A
B
G
B
6