P E I C C I F T A O I N S; Performance Data Of Swimming Pool Heat Pump Unit - Hayward HP50CLEE Installation Instructions Manual

Variable speed swimming pool heat pump
Table of Contents

Advertisement

Available languages

Available languages

2.SPECIFICATION

2.1 Performance data of Swimming Pool Heat Pump Unit

REFRIGERANT : R410A
UNIT
Rated Heating Power Input
Range
Rated Running Current Input
Range
Power Supply
Compressor Quantity
Compressor
Fan Quantity
Fan Power Input
Fan Rotate Speed
Fan Direction
Noise
Water Connection
Water Flow Volume
Water Pressure Drop(max)
Unit Net Dimensions
(L/W/H)
Unit Ship Dimensions
(L/W/H)
Net Weight
Shipping Weight
Rated Heating: *Outdoor air temp: 27℃/24.3℃, Inlet water temp:26.7℃
During heating: Running ambient temperature: -5℃~43℃.
Model
HP50CLEE
kW
2.68
kW
0.2-2.68
A
12.0
A
1.1-12.0
V/Hz
208-230V~/60Hz
1
rotary
1
W
100
RPM
500-650
horizontal
dB(A)
43-53
inch
1.5''
m3/h /gpm
4.1/18
kPa/psi
4.3/ 0.62
mm/ in
1048×442×770/
41.2×17.4×30.3
mm/ in
1130×460×780/
44.5×18.1×30.7
kg
kg
HP65CLEE
3.35
0.25 3.35
14.6
1.2 14.6
208-230V /60Hz
208-230V~/60Hz
1
rotary
1
75
400-700
horizontal
38-54
1.5''
5.1/22.5
5.2/0.75
1165×485×870/
45.9×19.1×34.3
1210×510×880/
47.6×20.1×34.6
see nameplate
see package label
HP75CLEE
3.86
0.31-3.86
16.9
1.5-16.9
1
rotary
1
100
300-750
horizontal
42-57
1.5''
6.2/ 27.3
4.9/ 0.71
1165×485×870/
45.9×19.1×34.3
1210×510×880/
47.6×20.1×34.6
2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hp65cleeHp75clee