CAMDEN CV-603 Installation Instructions Manual page 7

Mproxble controller/ mproxble controller cabinet kit
Table of Contents

Advertisement

Bill of material:
Item
Description
1
Controller
2
DC Power Supply
3
Transformer
4
Door Strike, 12 VDC
5
Door Relay
Door Position Switch, a door latch
6
monitor switch can be used, add
suffix "L" to CX-ED1079
Proximity Card Reader, 125 KHz.
7
Not required if transmitters are
used.
8
Request to Exit Device
9
Alarm Annunciator
System Operation:
a)
The system operation is identical to the single door operation (a) and (b).
b)
If the credential is approved by the controller, the door strike will energize for the pre-set period duration on the Cx-12 PLUS module.
The door operator will trigger to operate after the door strike has been energized. Once the pre-set periods have expired, the door ope-
rator and strike shall de-energize from the Cx-12PLUS module.
c)
Users exiting the door, must be detected by the request to exit device; manually by a push switch or auto matically using a PIR detector.
Opening the door without a request to exit switch shall cause the controller to generate a door forced open alarm
d)
An alarm annunciator shall be triggered for the following selected alarm conditions. Relay 2 must be config ured for ALARM and Relay 1
configuration must have door contact ON to activate these alarm conditions.
a. Intrusion
b. Door not opened after an approved credential read.
c. Door not closed after access. Alerts managers when the door is being left open.
d. Anti-passback
e. Access denied by location – Attempts made by credentials not approved by either reader 1, channel 1, reader 2 or channel 2.
f. Access denied by schedule.
g. Unknown user – a credential not enrolled into the controller user data base.
e)
Administrators shall use the app to control and configure the CV-603 controller using wireless Bluetooth. A steady on blue LED on the
CV-603 controller will confirm the connection.
CV-603 MPROXBLE CONTROLLER / CV-603PS-K1 MPROXBLE CONTROLLER CABINET KIT
Camden Model#
Quantity
CV-603PS-K1
1
CV-603 provided in kit
1
60-69B002 - provided in kit
1
CX-TRP-4016 provided in kit
1
CX-ED1079
1
CX-12PLUS
1
CX-MDA surface or CX-MDH recessed.
1
CV-7400
CM-RQE70 PIR sensor or CM-30E Push
1
button.
1
CM-AF142SO
INSTAL L AT ION INS T RUCT IONS
Camden Model#
CV-603
CV-603
PS-13
CX-TRP-4016
CX-ED1079
CX-12PLUS
CX-MDA surface or CX-MDH re-
cessed.
CV-7400
CM-RQE70 PIR sensor or CM-30E
Push button.
CM-AF142SO
Page 7 of 20