CV-603 MPROXBLE CONTROLLER / CV-603PS-K1 MPROXBLE CONTROLLER CABINET KIT
I NS TA L L AT IO N I NST RUCT I ONS
FEATURE RESTRICTIONS AND LIMITATIONS
 
Momentary
 
Conditional
ON or OFF
Input
Door
ON or OFF
Contact
Select
Schedule
one of the
reading ID
predefined
schedules.
Select
Lock and
one of the
unlock
predefined
Schedule
schedules.
First Person
ON or OFF
In Delay
Unlock Time
Not Available
Door Ajar
Not Available
Limit
Alarm
Shut-Off
Not Available
Period
On Relay 2 ONLY
For applications requiring a common alarm annunciation, relay 2 can be wired to an audible-visual device to alert security
personnel to an alarm condition.
Click on Relay 2 mode field, to pop open relay operating mode choices. You will notice 'Alarm' as an additional selection. Click on
'Alarm' to open alarm selections below.
Page 16 of 20
Bistable or
Timed
latching
ON or OFF
Not Available
ON or OFF
{If ALARM features
including intrusion,
door not opened or
Not Available
door ajar are to be
activated, this must
be on.}
Select one of
Select one of
the predefined
the predefined
schedules.
schedules.
Select one of
Select one of
the predefined
the predefined
schedules.
schedules.
ON or OFF
ON or OFF
In 00h: 00m: 00s:
Not Available
In 00h: 00m: 00s:
Not Available
Not Available
Not Available
Alarm
ONLY Available
for Relay 2
This selection will prevent the respective
relay to activate unless the controller
validation terminals VAL1 or VAL2 are
Not Available
normally closed while a credential is being
presented. To prevent vehicle tailgating this
feature is turned on.
This will monitor the validation terminals
VAL1 and VAL2 wired to a normally closed,
door position switch. When active, the
relay energized period will immediately
turn off as soon as the door is opened
Not Available
to immediately relock the door as soon
as it closes. Use this feature to prevent
unauthorized entry by individuals
reopening the door during the door release
period.
Select the schedule you wish for the selected
mode to function. The default schedules;
Not Available
NEVER and ALWAYS will be available. If you
added more schedules, you can select the
schedule previously defined.
The relay will automatically activate to the
Not Available
schedule selected.
The relay will not automatically activate
(open) until an authorized credential
is used. This is to prevent a relay to be
Not Available
energized unless an employee has entered
the facility. Schedule forced opening must
not be set to NEVER for this to appear.
Enter the time in hours, minutes, and
Not Available
seconds.
This feature is ideal for limiting the time
the door can remain open to prevent
In 00h: 00m: 00s:
unauthorized entry. The field appears only
when the Door Contact is switched on.
Enter the maximum time in hours, minutes
In 00h: 00m: 00s:
and seconds before the relay automatically
de-energizes.
Description