Group Configuration - CAMDEN CV-603 Installation Instructions Manual

Mproxble controller/ mproxble controller cabinet kit
Table of Contents

Advertisement

ALARM Conditions
Alarm, Intrusion
Alarm, door not open
Alarm, door not closed
Alarm, user anti-pass back
Alarm, access denied by location
Alarm, access denied by time schedule
Alarm, access denied by date schedule
Alarm, Unknown User
Once you have made the selections, click on the VALIDATE icon. A pop-up alert message will appear to confirm your settings have been
saved. Click ok to close.
Alarm Output: RELAY2 is used for common alarm notifications when selected. RELAY 1 must be set to 'TIMED' mode.

9. Group Configuration:

Every user must be assigned to a group. You can select to
turn any group on or off from this screen.
a.
[Name] You can change the default group STANDARD
or add a new name up to 17 characters.
b.
[Type] Tap on the default setting Badge/Transmitter
and a pop-up selection will appear. Select the type of
credential that will be accepted for this group.
i.
Badge = Only cards or tags that are read inches
away from a proximity card reader wired to the
controller Reader 1 or Reader 2 terminals.
ii.
Transmitter = Only battery powered, two button
transmitters that can be read over 100 feet from the
MProxBLE Controller.
iii.
Badge/Transmitter = Both types of credentials will
be accepted.
c.
[Schedule] Tap on the field right of the label to see one
of the three default schedules for the group. Additional
schedules can be added from the main menu selection
under schedules.
i.
Always – The group will always be active.
ii.
Never – The group will never be active
iii.
Standard – The active time and dates are defined
in schedules.
CV-603 MPROXBLE CONTROLLER / CV-603PS-K1 MPROXBLE CONTROLLER CABINET KIT
Requirements
Relay 1 Door Contact must be ON
Relay 1 Door Contact must be ON
Relay 1 Door Contact must be ON
ON or OFF
ON or OFF
ON or OFF
ON or OFF
ON or OFF
INSTAL L AT ION INS T RUCT IONS
Description
If the door is opened without a valid credential,
an alarm condition will occur.
If the door is not opened after a valid
credential, an alarm condition will occur.
If the door is left open past the relay unlock
time, an alarm condition will occur.
If a user violates the anti-pass back condition,
an alarm condition will occur.
If a credential is used on unapproved reader,
an alarm condition will occur.
If a credential is used outside the time period
selected, an alarm condition will occur.
If a credential is used outside the dates
selected, an alarm condition will occur.
If an unknown credential is used, an alarm
condition will occur.